Literature DB >> 26984914

Dynamic Stabilization with Active Locking Plates Delivers Faster, Stronger, and More Symmetric Fracture-Healing.

Michael Bottlang1, Stanley Tsai2, Emily K Bliven2, Brigitte von Rechenberg3, Karina Klein3, Peter Augat4, Julia Henschel5, Daniel C Fitzpatrick6, Steven M Madey2.   

Abstract

BACKGROUND: Axial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates.
METHODS: Twelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure.
RESULTS: At each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap.
CONCLUSIONS: Symmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. CLINICAL RELEVANCE: The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.
Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 26984914      PMCID: PMC4788849          DOI: 10.2106/JBJS.O.00705

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  42 in total

1.  Biomechanical properties in titanium implants with integrated maintenance free shock absorbing elements.

Authors:  A Gaggl; G Schultes
Journal:  Biomaterials       Date:  2001-11       Impact factor: 12.479

Review 2.  Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology.

Authors:  Stephan M Perren
Journal:  J Bone Joint Surg Br       Date:  2002-11

3.  Axial movement and tibial fractures. A controlled randomised trial of treatment.

Authors:  J Kenwright; J B Richardson; J L Cunningham; S H White; A E Goodship; M A Adams; P A Magnussen; J H Newman
Journal:  J Bone Joint Surg Br       Date:  1991-07

4.  Far cortical locking enables flexible fixation with periarticular locking plates.

Authors:  Josef Doornink; Daniel C Fitzpatrick; Steven M Madey; Michael Bottlang
Journal:  J Orthop Trauma       Date:  2011-02       Impact factor: 2.512

5.  Biomechanical principles and mechanobiologic aspects of flexible and locked plating.

Authors:  Lutz Claes
Journal:  J Orthop Trauma       Date:  2011-02       Impact factor: 2.512

6.  Anatomically neutral silicone small joint arthroplasty for osteoarthritis.

Authors:  Surena Namdari; Arnold-Peter C Weiss
Journal:  J Hand Surg Am       Date:  2009-02       Impact factor: 2.230

Review 7.  Biomechanics of locked plates and screws.

Authors:  Kenneth A Egol; Erik N Kubiak; Eric Fulkerson; Frederick J Kummer; Kenneth J Koval
Journal:  J Orthop Trauma       Date:  2004-09       Impact factor: 2.512

8.  The influence of induced micromovement upon the healing of experimental tibial fractures.

Authors:  A E Goodship; J Kenwright
Journal:  J Bone Joint Surg Br       Date:  1985-08

9.  Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?

Authors:  Karl Stoffel; Ulrich Dieter; Gwidon Stachowiak; André Gächter; Markus S Kuster
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

10.  Controlled dynamic stability as the next step in "biologic plate osteosynthesis" - a pilot prospective observational cohort study in 34 patients with distal tibia fractures.

Authors:  Thomas Freude; Steffen Schröter; Christoph Emanuel Gonser; Ulrich Stöckle; Yves P Acklin; Dankwart Höntzsch; Stefan Döbele
Journal:  Patient Saf Surg       Date:  2014-01-21
View more
  9 in total

1.  From Bench to Bedside: How Stiff is Too Stiff? Far-cortical Locking or Dynamic Locked Plating May Obviate the Question.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2016-05-10       Impact factor: 4.176

2.  Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.

Authors:  Steven M Madey; Stanley Tsai; Daniel C Fitzpatrick; Kathleen Earley; Michael Lutsch; Michael Bottlang
Journal:  Iowa Orthop J       Date:  2017

3.  From Bench to Bedside: Semper Gumby-Like Living Tissue, Let's Stay Flexible.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

4.  Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating.

Authors:  Michael Bottlang; Stanley Tsai; Emily K Bliven; Brigitte von Rechenberg; Philipp Kindt; Peter Augat; Julia Henschel; Daniel C Fitzpatrick; Steven M Madey
Journal:  J Orthop Trauma       Date:  2017-02       Impact factor: 2.512

5.  Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion.

Authors:  Julia Henschel; Stanley Tsai; Daniel C Fitzpatrick; J Lawrence Marsh; Steven M Madey; Michael Bottlang
Journal:  J Orthop Trauma       Date:  2017-10       Impact factor: 2.512

Review 6.  A Concert between Biology and Biomechanics: The Influence of the Mechanical Environment on Bone Healing.

Authors:  Vaida Glatt; Christopher H Evans; Kevin Tetsworth
Journal:  Front Physiol       Date:  2017-01-24       Impact factor: 4.566

7.  Variable fixation promotes callus formation: an experimental study on transverse tibial osteotomies stabilized with locking plates.

Authors:  Michael Plecko; Karina Klein; Katrin Planzer; Dirk Wähnert; Pascal Behm; Stephen J Ferguson; Stefano Brianza; Vincent A Stadelmann; Brigitte von Rechenberg
Journal:  BMC Musculoskelet Disord       Date:  2020-12-03       Impact factor: 2.362

8.  Association of Gap Healing With Angle of Correction After Opening-Wedge High Tibial Osteotomy Without Bone Grafting.

Authors:  Hyung Jun Park; Seung-Baik Kang; Moon Jong Chang; Chong Bum Chang; Woon Hwa Jung; Heejin Jin
Journal:  Orthop J Sports Med       Date:  2021-05-11

9.  Posterior spinal instrumentation and decompression with or without cross-link?

Authors:  Marco D Burkhard; Frédéric Cornaz; José Miguel Spirig; Florian Wanivenhaus; Rafael Loucas; Marie-Rosa Fasser; Jonas Widmer; Mazda Farshad
Journal:  N Am Spine Soc J       Date:  2021-11-17
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.