Coagulation and oxidation for controlling ultrafiltration membrane fouling in drinking water treatment: Application of ozone at low dose in submerged membrane tank.

Wenzheng Yu1, Nigel J D Graham2, Geoffrey D Fowler3.   

Abstract

Coagulation prior to ultrafiltration (UF) is widely applied for treating contaminated surface water sources for potable supply. While beneficial, coagulation alone is unable to control membrane fouling effectively in many cases, and there is continuing interest in the use of additional, complementary methods such as oxidation in the pre-treatment of raw water prior to UF. In this study, the application of ozone at low dose in the membrane tank immediately following coagulation has been evaluated at laboratory-scale employing model raw water. In parallel tests with and without the application of ozone, the impact of applied ozone doses of 0.5 mg L(-1) and 1.5 mg L(-1) (approximately 0.18 mg L(-1) and 0.54 mg L(-1) consumed ozone, respectively) on the increase of trans-membrane pressure (TMP) was evaluated and correlated with the quantity and nature of membrane deposits, both as a cake layer and within membrane pores. The results showed that a dose of 0.5 mgO3 L(-1) gave a membrane fouling rate that was substantially lower than without ozone addition, while a dose of 1.5 mgO3 L(-1) was able to prevent fouling effects significantly (no increase in TMP). Ozone was found to decrease the concentration of bacteria (especially the concentration of bacteria per suspended solid) in the membrane tank, and to alter the nature of dissolved organic matter by increasing the proportion of hydrophilic substances. Ozone decreased the concentration of extracellular polymeric substances (EPS), such as polysaccharides and proteins, in the membrane cake layer; the reduced EPS and bacterial concentrations resulted in a much thinner cake layer, although the suspended solids concentration was much higher in the ozone added membrane tank. Ozone also decreased the accumulation and hydrophobicity of organic matter within the membrane pores, leading to minimal irreversible fouling. Therefore, the application of low-dose ozone within the UF membrane tank is a potentially important approach for fully mitigating membrane fouling. Crown
Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Coagulation; Fouling; Oxidation; Ozone; Pre-treatment; Ultrafiltration

Mesh:

Substances:

Year:  2016        PMID: 26978716     DOI: 10.1016/j.watres.2016.02.063

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Reversible and irreversible membrane fouling in hollow-fiber UF membranes filtering surface water: effects of ozone/powdered activated carbon treatment.

Authors:  Weiwei Huang; Yuanhong Zhu; Lin Wang; Weiguang Lv; Bingzhi Dong; Wenzong Zhou
Journal:  RSC Adv       Date:  2021-03-10       Impact factor: 3.361

2.  Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance.

Authors:  Daoji Wu; Weiwei Zhou; Xiaoxiang Cheng; Congwei Luo; Peijie Li; Fengzhi Zhang; Zixiao Ren
Journal:  RSC Adv       Date:  2019-06-27       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.