Literature DB >> 26977760

Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study.

Yu Shi1, Fei Xia2, Qiu-Ju Li1, Jia-Hui Li1, Bing Yu1, Yue Li3, He An1, Kevin J Glaser4, Shengzhen Tao4, Richard L Ehman4, Qi-Yong Guo1.   

Abstract

OBJECTIVES: Magnetic resonance elastography (MRE) with three-dimensional spin-echo echo planar imaging (3D-SE-EPI) is a newly emerging noninvasive method for assessing liver fibrosis. We hypothesized that 3D-SE-EPI might have better diagnostic accuracy than conventional two-dimensional gradient-recalled echo (2D-GRE).
METHODS: We prospectively included 179 consecutive patients with chronic hepatitis B (CHB) or C (CHC) who underwent both MRE and liver biopsy. Liver stiffness was measured by both 3D-SE-EPI and 2D-GRE for staging biopsy-proven liver fibrosis (using METAVIR scores). A receiver-operating characteristic analysis using the area under the receiver-operating characteristic curve (AUC) was used to compare the diagnostic performance in predicting liver fibrosis between these two techniques, and compared them to serum markers of fibrosis.
RESULTS: The technical failure rate of 3D-SE-EPI (2.2%, n=4/179) was lower compared with 2D-GRE (8.3%, n=15/179). The stiffness measured by 3D-SE-EPI was slightly lower compared with 2D-GRE, with the mean difference of 0.57 kPa (Bland and Altman plot, 95% limits of agreement: -0.32 and 1.45 kPa). AUCs for the characterization of ≥F1, ≥F2, ≥F3, and F4 were 0.957 (95% confidence interval (CI): 0.913-0.983), 0.971 (0.932-0.991), 0.991 (0.961-0.999), and 0.979 (0.942-0.995) for 3D-SE-EPI, which was slightly higher compared with the AUCs for 2D-GRE at each fibrosis stage (0.948 (0.901-0.977), 0.959 (0.915-0.981), 0.979 (0.943-0.995), and 0.976 (0.938-0.994), respectively), although none reached statistical significance (P=0.160-0.585). In an "intention-to-diagnose" analysis, the diagnostic accuracy (the proportion of well-classified patients) by EPI (86.7-91.3%, n=169) was higher compared with GRE (80.9-82.1%, n=158) after applying optimal cutoffs. Both 3D-SE-EPI and 2D-GRE performed better than serum fibrosis markers.
CONCLUSIONS: With respect to 2D-GRE, 3D-SE-EPI has the advantage of lower failure rate with equivalent high diagnostic performance for staging liver fibrosis in CHB/CHC patients, and thus more helpful for those challenging cases in 2D-GRE.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26977760     DOI: 10.1038/ajg.2016.56

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  49 in total

1.  Spatio-temporal directional filtering for improved inversion of MR elastography images.

Authors:  A Manduca; D S Lake; S A Kruse; R L Ehman
Journal:  Med Image Anal       Date:  2003-12       Impact factor: 8.545

2.  Magnetic resonance elastography of the liver: preliminary results and estimation of inter-rater reliability.

Authors:  Utaroh Motosugi; Tomoaki Ichikawa; Katsuhiro Sano; Hironobu Sou; Ali Muhi; Tsuyota Koshiishi; Richard L Ehman; Tsutomu Araki
Journal:  Jpn J Radiol       Date:  2010-10-24       Impact factor: 2.374

3.  MRI-guided biopsy to correlate tissue specimens with MR elastography stiffness readings in liver transplants.

Authors:  Ryan B Perumpail; Josh Levitsky; Yi Wang; Victoria S Lee; Jennifer Karp; Ning Jin; Guang-Yu Yang; Bradley D Bolster; Saurabh Shah; Sven Zuehlsdorff; Albert A Nemcek; Andrew C Larson; Frank H Miller; Reed A Omary
Journal:  Acad Radiol       Date:  2012-09       Impact factor: 3.173

4.  Short- and midterm repeatability of magnetic resonance elastography in healthy volunteers at 3.0 T.

Authors:  Yu Shi; Qiyong Guo; Fei Xia; Jiaxing Sun; Yuying Gao
Journal:  Magn Reson Imaging       Date:  2014-02-18       Impact factor: 2.546

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Repeatability of magnetic resonance elastography for quantification of hepatic stiffness.

Authors:  Catherine D G Hines; Thorsten A Bley; Mary J Lindstrom; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2010-03       Impact factor: 4.813

7.  Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations.

Authors:  Meng Yin; Kevin J Glaser; Jayant A Talwalkar; Jun Chen; Armando Manduca; Richard L Ehman
Journal:  Radiology       Date:  2015-07-08       Impact factor: 11.105

8.  Comparative assessment of liver fibrosis by computerized morphometry in naïve patients with chronic hepatitis B and C.

Authors:  Nathalie Sturm; Alice Marlu; Philippe Arvers; Jean-Pierre Zarski; Vincent Leroy
Journal:  Liver Int       Date:  2013-03       Impact factor: 5.828

9.  MR elastography for the assessment of hepatic fibrosis in patients with chronic hepatitis B infection: does histologic necroinflammation influence the measurement of hepatic stiffness?

Authors:  Yu Shi; Qiyong Guo; Fei Xia; Bogdan Dzyubak; Kevin J Glaser; Qiuju Li; Jiahui Li; Richard L Ehman
Journal:  Radiology       Date:  2014-06-02       Impact factor: 11.105

10.  Noninvasive assessment of hepatic fibrosis in patients with chronic hepatitis B viral infection using magnetic resonance elastography.

Authors:  Jeong Eun Lee; Jeong Min Lee; Kyung Bun Lee; Jeong Hee Yoon; Cheong Il Shin; Joon Koo Han; Byung Ihn Choi
Journal:  Korean J Radiol       Date:  2014-03-07       Impact factor: 3.500

View more
  26 in total

1.  Comparison of diffusion-weighted imaging and MR elastography in staging liver fibrosis: a meta-analysis.

Authors:  Weon Jang; Seongil Jo; Ji Soo Song; Hong Pil Hwang; Seong-Hun Kim
Journal:  Abdom Radiol (NY)       Date:  2021-03-26

2.  Editorial: A New Spin on Magnetic Resonance Elastography.

Authors:  Rekha Kishore; Rohit Loomba; Richard K Sterling
Journal:  Am J Gastroenterol       Date:  2016-06       Impact factor: 10.864

Review 3.  Origins of Portal Hypertension in Nonalcoholic Fatty Liver Disease.

Authors:  Gyorgy Baffy
Journal:  Dig Dis Sci       Date:  2018-01-22       Impact factor: 3.199

Review 4.  MR elastography of liver: current status and future perspectives.

Authors:  Ilkay S Idilman; Jiahui Li; Meng Yin; Sudhakar K Venkatesh
Journal:  Abdom Radiol (NY)       Date:  2020-07-23

5.  Feasibility and agreement of stiffness measurements using gradient-echo and spin-echo MR elastography sequences in unselected patients undergoing liver MRI.

Authors:  Guilherme Moura Cunha; Kevin J Glaser; Anke Bergman; Rodrigo P Luz; Eduardo H de Figueiredo; Flavia Paiva Proença Lobo Lopes
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

Review 6.  Quantitative Elastography Methods in Liver Disease: Current Evidence and Future Directions.

Authors:  Paul Kennedy; Mathilde Wagner; Laurent Castéra; Cheng William Hong; Curtis L Johnson; Claude B Sirlin; Bachir Taouli
Journal:  Radiology       Date:  2018-03       Impact factor: 11.105

7.  Pancreatic Stiffness Quantified with MR Elastography: Relationship to Postoperative Pancreatic Fistula after Pancreaticoenteric Anastomosis.

Authors:  Yu Shi; Ying Liu; Feng Gao; Yanqing Liu; Shengzhen Tao; Yue Li; Kevin J Glaser; Richard L Ehman; Qiyong Guo
Journal:  Radiology       Date:  2018-04-17       Impact factor: 11.105

8.  Comparison of diagnostic accuracies of two- and three-dimensional MR elastography of the liver.

Authors:  Hiroyuki Morisaka; Utaroh Motosugi; Kevin J Glaser; Shintaro Ichikawa; Richard L Ehman; Katsuhiro Sano; Tomoaki Ichikawa; Hiroshi Onishi
Journal:  J Magn Reson Imaging       Date:  2016-09-23       Impact factor: 4.813

9.  Pancreatic stiffness response to an oral glucose load in obese adults measured by magnetic resonance elastography.

Authors:  Ruoyun Ji; Jiahui Li; Ziying Yin; Yanqing Liu; Lizhuo Cang; Min Wang; Yu Shi
Journal:  Magn Reson Imaging       Date:  2018-05-04       Impact factor: 2.546

10.  Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration.

Authors:  Yong Seek Kim; Ji Soo Song; Stephan Kannengiesser; Seung Young Seo
Journal:  Eur Radiol       Date:  2017-03-13       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.