Literature DB >> 2697696

Clinical value of ultrasonography in the detection and removal of radiolucent foreign bodies.

R Crawford1, A B Matheson.   

Abstract

A series of 39 consecutive patients with a suspected retained foreign body in the hand and in whom standard soft issue radiographs were negative were examined by real-time, high-resolution ultrasound scan. At operation 20 patients had radiolucent foreign bodies (18 wood, 2 thorns) removed. Ultrasound scan correctly localized 19 of the foreign bodies before surgery and failed to detect one. No foreign body was found in 19 patients. Ultrasound scan falsely predicted the presence of a foreign body in two of these cases. High-resolution ultrasound scanning is a sensitive, accurate technique for diagnosing foreign bodies which are otherwise difficult to demonstrate by conventional radiographic techniques, and provides accurate three-dimensional localization of the object which is of value to the surgeon at operation.

Entities:  

Mesh:

Year:  1989        PMID: 2697696     DOI: 10.1016/0020-1383(89)90008-9

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  13 in total

1.  An unusual cause of locking.

Authors:  R Jandhyala; A Wilson; S Bhagat; J Lavelle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-05       Impact factor: 4.342

Review 2.  Ultrasonography for detecting a hog bristle in a finger: a case report and literature review.

Authors:  Sui-Yi Chao; Tai-Chung Chern; I-Ming Jou; Yao-Lung Kuo
Journal:  Int Wound J       Date:  2013-10-17       Impact factor: 3.315

3.  [Ultrasound imaging and localization of metal implants. A clinical study].

Authors:  W Grechenig; H G Clement; M Fellinger; P Schleifer; P N Tesch
Journal:  Unfallchirurgie       Date:  1996-06

4.  Cactus thorn detection using bedside ultrasound.

Authors:  Karl Andrew Yousef; Aaron John Goshinska; Zachary P Bailowitz; Richard Amini
Journal:  Intern Emerg Med       Date:  2016-08-04       Impact factor: 3.397

5.  Ultrasound-Guided Removal of an Infected Loose Body from the Quadriceps Muscle.

Authors:  Rishi N Razdan; Tiffany Dube; Neil Specht
Journal:  Radiol Case Rep       Date:  2015-11-06

6.  Non-opaque soft tissue foreign body: sonographic findings.

Authors:  Afshin Mohammadi; Mohammad Ghasemi-Rad; Maryam Khodabakhsh
Journal:  BMC Med Imaging       Date:  2011-04-10       Impact factor: 1.930

7.  Use of point of care ultrasound for removal of foreign body: "Early screening of the neighborhood is the key".

Authors:  Jyotirmoy Das; Sangeeta Khanna; Sudhir Kumar; Ali Zamir Khan; Yatin Mehta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2016 Jul-Sep

8.  Ultrasonographically supported removal of foreign bodies of the eye lid and parapharyngeal space in a 13-year-old boy subjected to shot injuries in early childhood.

Authors:  Reinhard E Friedrich
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2013-11-29

9.  Surgical removal of neglected soft tissue foreign bodies by needle-guided technique.

Authors:  Ali Ebrahimi; Mohammad Radmanesh; Sohrab Rabiei; Hossein Kavoussi
Journal:  Iran J Otorhinolaryngol       Date:  2013

10.  Retrospective evaluation of 377 patients with penetrating foreign body injuries: a university hospital experience (a present case of missed sponge foreign body injury)

Authors:  Anıl Murat Öztürk; Omar Aljasim; Gamze Şanlıdağ; Meltem Taşbakan
Journal:  Turk J Med Sci       Date:  2021-04-30       Impact factor: 0.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.