Literature DB >> 26974632

Application of quantum weak measurement for glucose concentration detection.

Dongmei Li, Zhiyuan Shen, Yonghong He, Yilong Zhang, Zhenling Chen, Hui Ma.   

Abstract

A quantum weak measurement scheme based on a Mach-Zehnder interferometer is proposed to detect the concentration of glucose, bringing this mechanism into the field of biomedical sensing for the first time, to the best of our knowledge. With a Mach-Zehnder interferometer system, we can analyze tiny phase differences between the two paths by measuring spectrum shift. We measured the concentration of glucose with weak measurement to achieve a concentration resolution of 8.98×10⁻⁵ g/L corresponding to a volume refractive index of 1.39×10⁻⁸ RIU, which was more than five times higher than the resolution achieved by conventional interference, 4.99×10⁻⁴ g/L. In the detection of glucose concentration in the blood serum of mice, a resolution of 1.0136×10⁻⁷ g/L for weak measurement was obtained.

Entities:  

Year:  2016        PMID: 26974632     DOI: 10.1364/AO.55.001697

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  4 in total

1.  Rapid Separation of Enantiomeric Impurities in Chiral Molecules by a Self-Referential Weak Measurement System.

Authors:  Yang Xu; Lixuan Shi; Tian Guan; Suyi Zhong; Xuesi Zhou; Dongmei Li; Cuixia Guo; Yuxuan Yang; Xiangnan Wang; Zhangyan Li; Yonghong He; Luyuan Xie; Zonghan Gan
Journal:  Sensors (Basel)       Date:  2018-11-06       Impact factor: 3.576

2.  Label-free and Non-destruction Determination of Single- and Double-Strand DNA based on Quantum Weak Measurement.

Authors:  Tian Guan; Yuxuan Yang; Qianwen Zhang; Yonghong He; Naihan Xu; Dongmei Li; Lixuan Shi; Yang Xu; Xiangnan Wang
Journal:  Sci Rep       Date:  2019-02-13       Impact factor: 4.379

3.  An Optical Chiral Sensor Based on Weak Measurement for the Real-Time Monitoring of Sucrose Hydrolysis.

Authors:  Dongmei Li; Chaofan Weng; Yi Ruan; Kan Li; Guoan Cai; Chenyao Song; Qiang Lin
Journal:  Sensors (Basel)       Date:  2021-02-02       Impact factor: 3.576

4.  Determination of Tumor Marker Carcinoembryonic Antigen with Biosensor Based on Optical Quantum Weak Measurements.

Authors:  Tian Guan; Xiangnan Wang; Dongmei Li; Yilong Zhang; Yonghong He; Lixuan Shi; Yiqing Liu; Yuxuan Yang; Yang Xu; Rui Cui
Journal:  Sensors (Basel)       Date:  2018-05-14       Impact factor: 3.576

  4 in total