| Literature DB >> 26973814 |
Yutao U T Gong1, Jialu Yu2, Dalong Pang3, Heming Zhen4, James Galvin1, Ying Xiao5.
Abstract
Radiotherapy clinical-trial quality assurance is a crucial yet challenging process. This note presents a tool that automatically extracts dose/volume statistics for determining dosimetry compliance review with improved efficiency and accuracy. A major objective of this study is to develop an automated solution for clinical-trial radiotherapy dosimetry review.Entities:
Keywords: Matlab; automated data processing; clinical trial; quality assurance; radiation therapy plan evaluation
Year: 2016 PMID: 26973814 PMCID: PMC4776636 DOI: 10.3389/fonc.2016.00047
Source DB: PubMed Journal: Front Oncol ISSN: 2234-943X Impact factor: 6.244
Dosimetry-review workload of selected NRG trials (.
| Trial | No. of structures requiring review | No. of data points to be reviewed | Target accrual for trial |
|---|---|---|---|
| HN001 | 17 | 18 | 758 |
| HN002 | 9 | 14 | 296 |
| GU001 | 3 | 5 | 185 |
| LU001 | 6 | 14 | 168 |
| BN001 | 13 | 15 | 576 |
| GI001 | 10 | 16 | 182 |
Figure 1Typical work flow of DPS tool.
Figure 2Panel of dose/volume points statistics (DPS).
Figure 3Sample report spreadsheet for LU001 opened in Excel. The blue region on the top shows dosimetry-review requests entered in GUI, and the green region contains values of dose–volume points calculated by DPS. The red region is the statistics of values in the green region. Data shown in the table are made examples and are not from submitted cases.
Examples of expressions of dose/volume points and their definitions.
| Expressions | Definition |
|---|---|
| D(Gy)40(cc) | The dose in Gy that covers 40 cc of the structure |
| D(Gy)40(%) | The dose in Gy that covers 40% of the structure |
| D(%)40(cc) | The dose in percentage that covers 40 cc in the structure |
| D(%)40(%) | The dose in percentage that covers 40% of the structure |
| V(cc)40(Gy) | The volume in cc that is covered by a dose not <40 Gy |
| V(cc)40(%) | The volume in cc that is covered by a dose not <40% of the reference dose |
| V(%)40(Gy) | The volume in percentage that is covered by a dose not <40 Gy |
| V(%)40(%) | The volume in percentage that is covered by a dose not <40% of reference dose |
| Dmax | Maximum dose defined by RTOG, the same as D(Gy)0.03(cc) |
| Dmin | Minimum dose defined by RTOG, the lowest dose for a point in the volume that is at least 0.03 cc in size (found on the DVH curve at a volume that is the total volume of the structure – 0.03 cc) |
| Dmean | Mean dose in the structure |
| Dmean/Rx | Mean dose divided by the prescription dose |
| Dmean/Rx × 100 | Mean dose divided by the prescription dose and multiplied by 100 |
Figure 4An example DVH csv file opened in Excel. The file is partially displayed.