Literature DB >> 26971208

Apparatus and method for time-integrated, active sampling of contaminants in fluids demonstrated by monitoring of hexavalent chromium in groundwater.

Isaac B Roll1, Erin M Driver1, Rolf U Halden2.   

Abstract

Annual U.S. expenditures of $2B for site characterization invite the development of new technologies to improve data quality while reducing costs and minimizing uncertainty in groundwater monitoring. This work presents a new instrument for time-integrated sampling of environmental fluids using in situ solid-phase extraction (SPE). The In Situ Sampler (IS2) is an automated submersible device capable of extracting dissolved contaminants from water (100s-1000smL) over extended periods (hours to weeks), retaining the analytes, and rejecting the processed fluid. A field demonstration of the IS2 revealed 28-day average concentration of hexavalent chromium in a shallow aquifer affected by tidal stresses via sampling of groundwater as both liquid and sorbed composite samples, each obtained in triplicate. In situ SPE exhibited 75±6% recovery and an 8-fold improvement in reporting limit. Relative to use of conventional methods (100%), beneficial characteristics of the device and method included minimal hazardous material generation (2%), transportation cost (10%), and associated carbon footprint (2%). The IS2 is compatible with commercial SPE resins and standard extraction methods, and has been certified for more general use (i.e., inorganics and organics) by the Environmental Security Technology Certification Program (ESTCP) of the U.S. Department of Defense.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Active sampling; Environmental characterization; Hexavalent chromium; Solid-phase extraction; Time-integrated; Water sampling

Mesh:

Substances:

Year:  2016        PMID: 26971208      PMCID: PMC4826302          DOI: 10.1016/j.scitotenv.2016.03.011

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  16 in total

1.  Passive sampling and/or extraction techniques in environmental analysis: a review.

Authors:  Jacek Namieśnik; Bozena Zabiegała; Agata Kot-Wasik; Monika Partyka; Andrzej Wasik
Journal:  Anal Bioanal Chem       Date:  2004-10-23       Impact factor: 4.142

2.  Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water.

Authors:  Branislav Vrana; Graham A Mills; Ewa Dominiak; Richard Greenwood
Journal:  Environ Pollut       Date:  2005-12-15       Impact factor: 8.071

Review 3.  Passive sampling in environmental analysis.

Authors:  Suresh Seethapathy; Tadeusz Górecki; Xiaojing Li
Journal:  J Chromatogr A       Date:  2007-08-01       Impact factor: 4.759

4.  Time integrative passive sampling: how well do chemcatchers integrate fluctuating pollutant concentrations?

Authors:  Melanie Shaw; Jochen F Mueller
Journal:  Environ Sci Technol       Date:  2009-03-01       Impact factor: 9.028

5.  New device for time-averaged measurement of volatile organic compounds (VOCs).

Authors:  Noemí Santiago Sánchez; Sergio Tejada Alarcón; Rafael Tortajada Santonja; Julio Llorca-Pórcel
Journal:  Sci Total Environ       Date:  2014-01-02       Impact factor: 7.963

6.  Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water.

Authors:  Romain Jacquet; Cécile Miège; Foppe Smedes; Céline Tixier; Jacek Tronczynski; Anne Togola; Catherine Berho; Ignacio Valor; Julio Llorca; Bruno Barillon; P Marchand; Marina Coquery
Journal:  Chemosphere       Date:  2013-11-05       Impact factor: 7.086

7.  Indoor air condensate as a novel matrix for monitoring inhalable organic contaminants.

Authors:  Isaac B Roll; Rolf U Halden; Benny F G Pycke
Journal:  J Hazard Mater       Date:  2015-01-21       Impact factor: 10.588

8.  Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

Authors:  Alissa L Coes; Nicholas V Paretti; William T Foreman; Jana L Iverson; David A Alvarez
Journal:  Sci Total Environ       Date:  2014-01-11       Impact factor: 7.963

9.  Time-integrated monitoring of polycyclic aromatic hydrocarbons (Pahs) in groundwater using the ceramic dosimeter passive sampling device.

Authors:  Stephanie Bopp; Hansjörg Weiss; Kristin Schirmer
Journal:  J Chromatogr A       Date:  2005-04-22       Impact factor: 4.759

10.  Active Sampling Device for Determining Pollutants in Surface and Pore Water - the In Situ Sampler for Biphasic Water Monitoring.

Authors:  Samuel D Supowit; Isaac B Roll; Viet D Dang; Kevin J Kroll; Nancy D Denslow; Rolf U Halden
Journal:  Sci Rep       Date:  2016-02-24       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.