Literature DB >> 26970347

High-performance liquid chromatography with diode array detection method for the simultaneous determination of seven selected phosphodiesterase-5 inhibitors and serotonin reuptake inhibitors used as male sexual enhancers.

Mostafa M Baker1, Tarek S Belal2, Mohamed S Mahrous3, Hytham M Ahmed4, Hoda G Daabees5.   

Abstract

This work presents a simple, sensitive and generic high-performance liquid chromatography with diode array detection method for the simultaneous determination of seven drugs prescribed for the treatment of erectile dysfunction and premature ejaculation. Investigated drugs include the phosphodiesterase-5 inhibitors: sildenafil, tadalafil, and vardenafil, in addition to the selective serotonin reuptake inhibitors: dapoxetine, duloxetine, fluoxetine, and paroxetine. The drugs were separated using a Waters C8 column (4.6 × 250 mm, 5 μm) with the mobile phase consisting of phosphate buffer pH 3, acetonitrile and methanol in the ratio 60:33:7. The flow rate was 1.2 mL/min, and quantification was based on measuring peak areas at 225 nm. Peaks were perfectly resolved with retention times 3.3, 3.9, 6.4, 7.5, 9.5, 10.7, and 13.4 min for vardenafil, sildenafil, paroxetine, duloxetine, dapoxetine, fluoxetine, and tadalafil, respectively. The developed method was validated with respect to system suitability, linearity, ranges, accuracy, precision, robustness, and limits of detection and quantification. The proposed method showed good linearity in the ranges 5-500, 2-200, 2-200, 3-300, 1.5-150, 2-200, and 2-200 μg/mL for sildenafil, tadalafil, vardenafil, dapoxetine, duloxetine fluoxetine, and paroxetine, respectively. The limits of detection were 0.18-0.38 μg/mL for the analyzed compounds. The applicability of the proposed method to real life situations was assessed through the analysis of commercial tablets, and satisfactory results were obtained.
© 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Diode array detection; High-performance liquid chromatography; Phosphodiesterase-5 inhibitors; Selective serotonin reuptake inhibitors; Tablet dosage forms

Mesh:

Substances:

Year:  2016        PMID: 26970347     DOI: 10.1002/jssc.201501339

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  5 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

2.  Electrochemical Determination of the Serotonin Reuptake Inhibitor, Dapoxetine, Using Cesium-Gold Nanoparticles.

Authors:  Mona A Mohamed; Shimaa A Atty; Ali M Yehia; Christopher W Foster; Craig E Banks; Nageh K Allam
Journal:  ACS Omega       Date:  2017-10-11

3.  HPLC-UV and UPLC-MS/MS methods for the simultaneous analysis of sildenafil, vardenafil, and tadalafil and their counterfeits dapoxetine, paroxetine, citalopram, tramadol, and yohimbine in aphrodisiac products.

Authors:  Mohamed A Abdelshakour; Randa A Abdel Salam; Ghada M Hadad; Dina M Abo-ElMatty; Eman A Abdel Hameed
Journal:  RSC Adv       Date:  2021-02-18       Impact factor: 3.361

4.  Simultaneous determination of Avanafil and Dapoxetine in human plasma using liquid chromatography/tandem mass spectrometry (LC-MS/MS) based on a protein precipitation technique.

Authors:  Mona N Abou-Omar; Abdelaziz M Annadi; Noha M El Zahar; Ahmed O Youssef; Mohammed A Amin; Mohamed S Attia; Ekram H Mohamed
Journal:  RSC Adv       Date:  2021-09-06       Impact factor: 4.036

5.  Core-shell particles and monolithic columns; tools for simultaneous LC analysis of avanafil, sildenafil, apomorphine, trazodone, yohimbine, tramadol and dapoxetine in pharmaceutical dosage forms, counterfeit products and human plasma.

Authors:  Adel Ehab Ibrahim; Hisham Hashem; Magda Elhenawee; Hanaa Saleh
Journal:  RSC Adv       Date:  2020-01-08       Impact factor: 4.036

  5 in total