Literature DB >> 26969304

Optical models of the human eye.

David A Atchison1, Larry N Thibos2.   

Abstract

Optical models of the human eye have been used in visual science for purposes such as providing a framework for explaining optical phenomena in vision, for predicting how refraction and aberrations are affected by change in ocular biometry and as computational tools for exploring the limitations imposed on vision by the optical system of the eye. We address the issue of what is understood by optical model eyes, discussing the 'encyclopaedia' and 'toy train' approaches to modelling. An extensive list of purposes of models is provided. We discuss many of the theoretical types of optical models (also schematic eyes) of varying anatomical accuracy, including single, three and four refracting surface variants. We cover the models with lens structure in the form of nested shells and gradient index. Many optical eye models give accurate predictions only for small angles and small fields of view. If aberrations and image quality are important to consider, such 'paraxial' model eyes must be replaced by 'finite model' eyes incorporating features such as aspheric surfaces, tilts and decentrations, wavelength-dependent media and curved retinas. Many optical model eyes are population averages and must become adaptable to account for age, gender, ethnicity, refractive error and accommodation. They can also be customised for the individual when extensive ocular biometry and optical performance data are available. We consider which optical model should be used for a particular purpose, adhering to the principle that the best model is the simplest fit for the task. We provide a glimpse into the future of optical models of the human eye. This review is interwoven with historical developments, highlighting the important people who have contributed so richly to our understanding of visual optics.
© 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.

Entities:  

Keywords:  finite models; optical models; paraxial models; schematic eyes; visual optics

Mesh:

Year:  2016        PMID: 26969304     DOI: 10.1111/cxo.12352

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  14 in total

Review 1.  IMI - Report on Experimental Models of Emmetropization and Myopia.

Authors:  David Troilo; Earl L Smith; Debora L Nickla; Regan Ashby; Andrei V Tkatchenko; Lisa A Ostrin; Timothy J Gawne; Machelle T Pardue; Jody A Summers; Chea-Su Kee; Falk Schroedl; Siegfried Wahl; Lyndon Jones
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-02-28       Impact factor: 4.799

Review 2.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

3.  Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models.

Authors:  Yongji Liu; Xiaolan Li; Lin Zhang; Xianglong Yi; Yuwei Xing; Kunqi Li; Yan Wang
Journal:  Biomed Opt Express       Date:  2022-08-25       Impact factor: 3.562

4.  3D Modeling of the Crystalline Lens Complex under Pseudoexfoliation.

Authors:  Leonor Jud; André P G Castro; Rui B Ruben; Bernardo Feijóo; Filomena J Ribeiro; Paulo R Fernandes
Journal:  Bioengineering (Basel)       Date:  2022-05-13

5.  Theoretical versus empirical measures of retinal magnification for scaling AOSLO images.

Authors:  H Heitkotter; A E Salmon; R E Linderman; J Porter; J Carroll
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2021-10-01       Impact factor: 2.104

Review 6.  Pharmacogenomic Approach to Antimyopia Drug Development: Pathways Lead the Way.

Authors:  Tatiana V Tkatchenko; Andrei V Tkatchenko
Journal:  Trends Pharmacol Sci       Date:  2019-10-30       Impact factor: 14.819

7.  Life Cycle and Lensing of a Macular Microcyst.

Authors:  Alexander Meadway; Alex S McKeown; Brian C Samuels; Lawrence C Sincich
Journal:  Ophthalmic Res       Date:  2020-01-08       Impact factor: 3.031

8.  Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model.

Authors:  Georgios Zoulinakis; Teresa Ferrer-Blasco
Journal:  J Ophthalmol       Date:  2017-03-30       Impact factor: 1.909

9.  A One-Step, Streamlined Children's Vision Screening Solution Based on Smartphone Imaging for Resource-Limited Areas: Design and Preliminary Field Evaluation.

Authors:  Shuoxin Ma; Yongqing Guan; Yazhen Yuan; Yuan Tai; Tan Wang
Journal:  JMIR Mhealth Uhealth       Date:  2020-07-13       Impact factor: 4.773

10.  Relief of Cystoid Macular Edema-Induced Focal Axonal Compression with Anti-Vascular Endothelial Growth Factor Treatment.

Authors:  Eyyup Karahan; Aliaa Abdelhakim; Ceren Durmaz; Tongalp H Tezel
Journal:  Transl Vis Sci Technol       Date:  2020-03-18       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.