Literature DB >> 26968422

Flexible proton 3D MR spectroscopic imaging of the prostate with low-power adiabatic pulses for volume selection and spiral readout.

Isabell K Steinseifer1, Bart W J Philips1, Borjan Gagoski2, Elisabeth Weiland3, Tom W J Scheenen1, Arend Heerschap1.   

Abstract

PURPOSE: Cartesian k-space sampling in three-dimensional magnetic resonance spectroscopic imaging (MRSI) of the prostate limits the selection of voxel size and acquisition time. Therefore, large prostates are often scanned at reduced spatial resolutions to stay within clinically acceptable measurement times. Here we present a semilocalized adiabatic selective refocusing (sLASER) sequence with gradient-modulated offset-independent adiabatic (GOIA) refocusing pulses and spiral k-space acquisition (GOIA-sLASER-Spiral) for fast prostate MRSI with enhanced resolution and extended matrix sizes.
METHODS: MR was performed at 3 tesla with an endorectal receive coil. GOIA-sLASER-Spiral at an echo time (TE) of 90 ms was compared to a point-resolved spectroscopy sequence (PRESS) with weighted, elliptical phase encoding at an TE of 145 ms using simulations and measurements of phantoms and patients (n = 9).
RESULTS: GOIA-sLASER-Spiral acquisition allows prostate MR spectra to be obtained in ∼5 min with a quality comparable to those acquired with a common Cartesian PRESS protocol in ∼9 min, or at an enhanced spatial resolution showing more precise tissue allocation of metabolites. Extended field of views (FOVs) and matrix sizes for large prostates are possible without compromising spatial resolution or measurement time.
CONCLUSION: The flexibility of spiral sampling enables prostate MRSI with a wide range of resolutions and FOVs without undesirable increases in acquisition times, as in Cartesian encoding. This approach is suitable for routine clinical exams of prostate metabolites. Magn Reson Med 77:928-935, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  GOIA; adiabatic pulses; prostate; semi-LASER; spectroscopic imaging; spiral k-space sampling

Mesh:

Substances:

Year:  2016        PMID: 26968422     DOI: 10.1002/mrm.26181

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Absolute choline tissue concentration mapping for prostate cancer localization and characterization using 3D 1 H MRSI without water-signal suppression.

Authors:  Nassim Tayari; Alan J Wright; Arend Heerschap
Journal:  Magn Reson Med       Date:  2021-09-23       Impact factor: 3.737

Review 2.  Basic concepts and applications of functional magnetic resonance imaging for radiotherapy of prostate cancer.

Authors:  Lars E Olsson; Mikael Johansson; Björn Zackrisson; Lennart K Blomqvist
Journal:  Phys Imaging Radiat Oncol       Date:  2019-02-25

Review 3.  Developments in proton MR spectroscopic imaging of prostate cancer.

Authors:  Angeliki Stamatelatou; Tom W J Scheenen; Arend Heerschap
Journal:  MAGMA       Date:  2022-04-20       Impact factor: 2.533

Review 4.  Accelerated MR spectroscopic imaging-a review of current and emerging techniques.

Authors:  Wolfgang Bogner; Ricardo Otazo; Anke Henning
Journal:  NMR Biomed       Date:  2020-05-12       Impact factor: 4.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.