Timothy Hudson Rainer1, Ling Yan Leung1, Cangel Pui Yee Chan1, Yuk Ki Leung1, Jill Morales Abrigo2, Defeng Wang2, Colin A Graham3. 1. Accident and Emergency Medicine Academic Unit, The Chinese University of Hong Kong, Hong Kong. 2. Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong. 3. Accident and Emergency Medicine Academic Unit, The Chinese University of Hong Kong, Hong Kong. Electronic address: cagraham@cuhk.edu.hk.
Abstract
OBJECTIVES: This study aimed to investigate plasma concentrations of miR-124-3p and miR-16 as prognostic markers in emergency department patients with acute stroke. DESIGN AND METHODS: Plasma concentrations of miR-124-3p and miR-16 of 84 stroke patients (presenting to the emergency department within 24h from onset of symptoms) were determined by RT-qPCR. The primary outcome measure was 3-month mortality and the secondary outcome measure was post-stroke modified Rankin Score (mRS). RESULTS: Twelve patients (14.3%) died within 3months of hospital admission and forty-one (48.8%) patients as achieved a 3-month mRS>2. Median plasma miR-124-3p concentrations were elevated in patients who died compared to patients who survived (p=0.0052), and its levels were found to be higher in patients with a 3-month mRS>2 compared with patients with mRS≤2 (p=0.0312). Higher plasma miR-16 concentrations were observed in patients who survived than in patients who died (p=0.0394), while its concentrations were lower in patients achieving mRS>2 than in patients with mRS≤2 (p=0.0124). For a subgroup of cases presenting to the emergency department within 6h from time of symptom onset (n=36), plasma miR-124-3p concentrations predicted 3-month mortality with an area under the ROC curve of 0.87 (95%CI: 0.72-0.96). CONCLUSIONS: Plasma miR-124-3p and miR-16 are molecular markers which could be useful for the early prediction of mortality and mRS.
OBJECTIVES: This study aimed to investigate plasma concentrations of miR-124-3p and miR-16 as prognostic markers in emergency department patients with acute stroke. DESIGN AND METHODS: Plasma concentrations of miR-124-3p and miR-16 of 84 strokepatients (presenting to the emergency department within 24h from onset of symptoms) were determined by RT-qPCR. The primary outcome measure was 3-month mortality and the secondary outcome measure was post-stroke modified Rankin Score (mRS). RESULTS: Twelve patients (14.3%) died within 3months of hospital admission and forty-one (48.8%) patients as achieved a 3-month mRS>2. Median plasma miR-124-3p concentrations were elevated in patients who died compared to patients who survived (p=0.0052), and its levels were found to be higher in patients with a 3-month mRS>2 compared with patients with mRS≤2 (p=0.0312). Higher plasma miR-16 concentrations were observed in patients who survived than in patients who died (p=0.0394), while its concentrations were lower in patients achieving mRS>2 than in patients with mRS≤2 (p=0.0124). For a subgroup of cases presenting to the emergency department within 6h from time of symptom onset (n=36), plasma miR-124-3p concentrations predicted 3-month mortality with an area under the ROC curve of 0.87 (95%CI: 0.72-0.96). CONCLUSIONS: Plasma miR-124-3p and miR-16 are molecular markers which could be useful for the early prediction of mortality and mRS.
Authors: Matthew A Edwardson; Xiaogang Zhong; Massimo S Fiandaca; Howard J Federoff; Amrita K Cheema; Alexander W Dromerick Journal: Sci Rep Date: 2018-08-22 Impact factor: 4.379