Literature DB >> 26964301

[Three-dimensional Finite Element Analysis to T-shaped Fracture of Pelvis in Sitting Position].

Yanping Fan, Jianyin Lei, Haibo Liu, Zhiqiang Li, Xianhua Cai, Weiyi Chen.   

Abstract

We developed a three-dimensional finite element model of the pelvis. According to Letournel methods, we established a pelvis model of T-shaped fracture with its three different fixation systems, i. e. double column reconstruction plates, anterior column plate combined with posterior column screws and anterior column plate combined with quadrilateral area screws. It was found that the pelvic model was effective and could be used to simulate the mechanical behavior of the pelvis. Three fixation systems had great therapeutic effect on the T-shaped fracture. All fixation systems could increase the stiffness of the model, decrease the stress concentration level and decrease the displacement difference along the fracture line. The quadrilateral area screws, which were drilled into cortical bone, could generate beneficial effect on the T-type fracture. Therefore, the third fixation system mentioned above (i. e. the anterior column plate combined with quadrilateral area screws) has the best biomechanical stability to the T-type fracture.

Entities:  

Mesh:

Year:  2015        PMID: 26964301

Source DB:  PubMed          Journal:  Sheng Wu Yi Xue Gong Cheng Xue Za Zhi        ISSN: 1001-5515


  1 in total

1.  Effects of minimally invasive plate-screw internal fixation in the treatment of posterior pelvic ring fracture.

Authors:  Shiguang Li; Xianxia Meng; Wenlong Li; Zhaoyun Sun; Xing Wang; Hongde Qi; Shuju Wei; Dongsheng Zhou
Journal:  Exp Ther Med       Date:  2018-08-31       Impact factor: 2.447

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.