Outcomes of double-balloon enteroscopy-assisted direct percutaneous endoscopic jejunostomy tube placement.

Badr Al-Bawardy1, Emmanuel C Gorospe1, Jeffrey A Alexander1, David H Bruining1, Nayantara Coelho-Prabhu1, Elizabeth Rajan1, Louis M Wong Kee Song1.   

Abstract

BACKGROUND AND STUDY AIMS: In a large series, conventional direct percutaneous endoscopic jejunostomy (DPEJ) tube placement with push endoscopes failed in approximately one-third of patients. In a pilot study, double-balloon enteroscopy (DBE)-assisted DPEJ tube placement was successful in all patients in whom attempted conventional DPEJ had failed. The study aim was to assess the technical success of and adverse events related to DBE-DPEJ tube placement in a large cohort of patients. PATIENTS AND METHODS: The medical records of all patients who underwent DBE-DPEJ tube placement between July 2010 and November 2013 were reviewed using a prospectively maintained electronic database. Data were abstracted for patient demographics, indications for DPEJ, gut anatomy, technical success rate, causes of failure, and adverse events.
RESULTS: The study comprised a total of 94 patients (39 men; mean age 56 years; body mass index [BMI] 23 ± 6.4 kg/m(2)). The most common indication for DPEJ was gastroparesis (n = 29). Altered gut anatomy was present in 36 patients (38 %). DBE-DPEJ tube placement was technically successful in 87 patients (93 %). The mean procedure duration was 33 minutes (range 15 - 88). DBE-DPEJ tube placement failed in seven patients (7 %), primarily because of limited instrument advancement in the setting of presumed surgical adhesions. Post-procedural adverse events occurred in eight patients (9 %), with one serious adverse event, which was a gastric interposition requiring surgical repair.
CONCLUSIONS: Compared with the published outcomes of DPEJ by conventional endoscopy, DBE-DPEJ tube placement was technically successful in a high proportion of patients (93 %) and with a relatively low rate of significant adverse events. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2016        PMID: 26964079     DOI: 10.1055/s-0042-101853

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  3 in total

Review 1.  Small Bowel Endoscopy.

Authors:  Dejan Micic; Carol E Semrad
Journal:  Curr Treat Options Gastroenterol       Date:  2016-06

Review 2.  Direct percutaneous endoscopic jejunostomy (DPEJ) and percutaneous endoscopic gastrostomy with jejunal extension (PEG-J) technical success and outcomes: Systematic review and meta-analysis.

Authors:  Smit S Deliwala; Saurabh Chandan; Anand Kumar; Babu Mohan; Anoosha Ponnapalli; Murtaza S Hussain; Sunil Kaushal; Joshua Novak; Saurabh Chawla
Journal:  Endosc Int Open       Date:  2022-04-14

3.  Direct percutaneous endoscopic jejunostomy tube placement in patients post Roux-en-Y gastric bypass, a single tertiary care center experience.

Authors:  Mahmoud Aryan; Tyler Colvin; Ramzi Mulki; Lauren Daley; Parth Patel; John Locke; Ali M Ahmed; Kondal R Kyanam Kabir Baig; Klaus Mönkemüller; Shajan Peter
Journal:  Endosc Int Open       Date:  2022-09-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.