Literature DB >> 26947376

Influence of caudal traction of ipsilateral arm on ultrasound image for supraclavicular central venous catheterization.

Eun-Hee Kim1, Ji-Hyun Lee1, In-Kyung Song1, Hyun-Chang Kim2, Hee-Soo Kim1, Jin-Tae Kim3.   

Abstract

BACKGROUND: The first step for successful ultrasound (US)-guided subclavian vein (SCV) catheterization using a supraclavicular approach is to obtain a good longitudinal image of SCV for in-plane needle placement. We evaluated the efficacy of caudal traction of ipsilateral arm on the exposure of the SCV.
METHODS: We enrolled 20 infants, 20 children, and 20 adults undergoing general anesthesia. After tracheal intubation, US probe was applied as the supraclavicular approach, and the longitudinal US image of SCV was obtained in 3 different ipsilateral arm positions: neutral, caudal traction, and abduction. The length of puncturable SCV, the diameter of SCV, and the available angle for needle insertion in 3 different arm positions were analyzed.
RESULTS: In all patients, the length of puncturable SCV and the available angle for needle insertion were significantly increased after caudal traction (35.6% ± 27.1% and 25.0% ± 19.3%, respectively) and decreased after the abduction (36.6% ± 22.9% and 29.5% ± 23.8%, respectively) compared to neutral position. The diameter of SCV was not changed after applying the caudal traction in infants and children. However, in adults, the caudal traction slightly increased the diameter of SCV (P = .012).
CONCLUSION: The caudal traction of ipsilateral arm toward to the knee improves the longitudinal US view of SCV for the supraclavicular approach, without reducing its size. Proper caudal traction of the arm might ensure the high success rate with safe needle insertion technique. Abduction should be avoided during US-guided supraclavicular SCV catheterization.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26947376     DOI: 10.1016/j.ajem.2016.01.038

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  2 in total

1.  Optimal angle of needle insertion for spinal anesthesia in patients with spondylolisthesis: an ultrasonographic study.

Authors:  Youngwon Kim; Seokha Yoo; Sun-Kyung Park; Hansu Bae; Young-Jin Lim; Jin-Tae Kim
Journal:  BMC Anesthesiol       Date:  2021-09-08       Impact factor: 2.217

2.  Supraclavicular or infraclavicular subclavian vein: Which way to go- A prospective randomized controlled trial comparing catheterization dynamics using ultrasound guidance.

Authors:  Ram Prasad; Shikha Soni; Sarita Janweja; Jogendra S Rajpurohit; Ram Nivas; Jagdish Kumar
Journal:  Indian J Anaesth       Date:  2020-03-28