Matrix effects of calcium on high-precision sulfur isotope measurement by multiple-collector inductively coupled plasma mass spectrometry.

Chenhui Liu1, Xiao-Peng Bian1, Tao Yang2, An-Jun Lin3, Shao-Yong Jiang4.   

Abstract

Multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has been successfully applied in the rapid and high-precision measurement for sulfur isotope ratios in recent years. During the measurement, the presence of matrix elements would affect the instrumental mass bias for sulfur and these matrix-induced effects have aroused a lot of researchers' interest. However, these studies have placed more weight on highlighting the necessity for their proposed correction protocols (e.g., chemical purification and matrix-matching) while less attention on the key property of the matrix element gives rise to the matrix effects. In this study, four groups of sulfate solutions, which have different concentrations of sulfur (0.05-0.60mM) but a constant sequence of atomic calcium/sulfur ratios (0.1-50), are investigated under wet (solution) and dry (desolvation) plasma conditions to make a detailed evaluation on the matrix effects from calcium on sulfur isotope measurement. Based on a series of comparative analyses, we indicated that, the matrix effects of calcium on both measured sulfur isotope ratios and detected (32)S signal intensities are dependent mainly on the absolute calcium concentration rather than its relative concentration ratio to sulfur (i.e., atomic calcium/sulfur ratio). Also, for the same group of samples, the matrix effects of calcium under dry plasma condition are much more significant than that of wet plasma. This research affords the opportunity to realize direct and relatively precise sulfur isotope measurement for evaporite gypsum, and further provides some suggestions with regard to sulfur isotope analytical protocols for sedimentary pore water.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Calcium concentration; MC-ICP-MS; Matrix effects; Sulfur isotope

Year:  2016        PMID: 26946020     DOI: 10.1016/j.talanta.2016.01.013

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

Authors:  Ondrej Hanousek; Marion Brunner; Daniel Pröfrock; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Methods       Date:  2016-09-23       Impact factor: 2.896

2.  An evaluation on the extraction capability of anion exchange membranes for high-precision sulfur isotope measurement by multiple-collector inductively coupled plasma mass spectrometry.

Authors:  Liu Willow Yang; Chenhui Liu; Tao Yang
Journal:  RSC Adv       Date:  2019-10-02       Impact factor: 3.361

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.