Literature DB >> 26945317

Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography.

Adrian Dalbert1, Alexander Huber, Dorothe Veraguth, Christof Roosli, Flurin Pfiffner.   

Abstract

OBJECTIVE: To assess cochlear trauma during cochlear implantation by electrocochleography (ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative cochlear trauma with postoperative loss of residual hearing.
METHODS: ECoG recordings to tone bursts at 250, 500, 750, and 1000 Hz and click stimuli were recorded before and after insertion of the cochlear implant electrode array, using an extracochlear recording electrode. CBCTs were conducted within 6 weeks after surgery. Changes of intraoperative ECoG recordings and CBCT findings were correlated with postoperative threshold shifts in pure-tone audiograms.
RESULTS: Fourteen subjects were included. In three subjects a decrease of low-frequency ECoG responses at 250, 500, 750, and 1000 Hz occurred after insertion of the electrode array. This was associated with no or minimal residual hearing 4 weeks after surgery. ECoG responses to click stimuli were present in six subjects and showed a decrease after insertion of the electrode array in three. This was associated with a mean hearing loss of 21 dB in postoperative pure-tone audiograms. Scalar dislocation of the electrode array was assumed in one subject because of CBCT findings and correlated with a decrease of low-frequency ECoG responses and a complete loss of residual hearing.
CONCLUSION: Hearing loss of ≤11 dB is not associated with detectable decrease in ECoG recordings during cochlear implantation. However, in a majority of patients with threshold shifts of >11 dB or complete hearing loss, an intraoperative decrease of high- or low-frequency ECoG signals occurs, suggesting acute cochlear trauma.

Entities:  

Mesh:

Year:  2016        PMID: 26945317     DOI: 10.1097/MAO.0000000000000998

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  16 in total

1.  Patterns Seen During Electrode Insertion Using Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant.

Authors:  Michael S Harris; William J Riggs; Christopher K Giardina; Brendan P O'Connell; Jourdan T Holder; Robert T Dwyer; Kanthaiah Koka; Robert F Labadie; Douglas C Fitzpatrick; Oliver F Adunka
Journal:  Otol Neurotol       Date:  2017-12       Impact factor: 2.311

2.  Cochlear Microphonics in Hearing Preservation Cochlear Implantees.

Authors:  Artur Lorens; Adam Walkowiak; Marek Polak; Aleksandra Kowalczuk; Mariusz Furmanek; Henryk Skarzynski; Anita Obrycka
Journal:  J Int Adv Otol       Date:  2019-12       Impact factor: 1.017

3.  Radiological evaluation of inner ear trauma after cochlear implant surgery by cone beam CT(CBCT).

Authors:  Tougan Taha Abd El Aziz; Lobna El Fiky; Mennatallah Hatem Shalaby; Ahmed Essam
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-06-13       Impact factor: 2.503

4.  Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography.

Authors:  Christopher K Giardina; Tatyana E Khan; Stephen H Pulver; Oliver F Adunka; Craig A Buchman; Kevin D Brown; Harold C Pillsbury; Douglas C Fitzpatrick
Journal:  Ear Hear       Date:  2018 Nov/Dec       Impact factor: 3.570

5.  Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation.

Authors:  Christopher K Giardina; Kevin D Brown; Oliver F Adunka; Craig A Buchman; Kendall A Hutson; Harold C Pillsbury; Douglas C Fitzpatrick
Journal:  Ear Hear       Date:  2019 Jul/Aug       Impact factor: 3.570

Review 6.  Electrocochleography in cochlear implantation: Development, applications, and future directions.

Authors:  Jason H Barnes; Linda X Yin; Aniket A Saoji; Matthew L Carlson
Journal:  World J Otorhinolaryngol Head Neck Surg       Date:  2020-06-04

7.  Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography.

Authors:  Adrian Dalbert; Flurin Pfiffner; Marco Hoesli; Kanthaiah Koka; Dorothe Veraguth; Christof Roosli; Alexander Huber
Journal:  Front Neurosci       Date:  2018-01-26       Impact factor: 4.677

8.  Intra- and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation.

Authors:  Brendan P O'Connell; Jourdan T Holder; Robert T Dwyer; René H Gifford; Jack H Noble; Marc L Bennett; Alejandro Rivas; George B Wanna; David S Haynes; Robert F Labadie
Journal:  Front Neurosci       Date:  2017-05-29       Impact factor: 4.677

9.  A Model-Based Approach for Separating the Cochlear Microphonic from the Auditory Nerve Neurophonic in the Ongoing Response Using Electrocochleography.

Authors:  Tatyana E Fontenot; Christopher K Giardina; Douglas C Fitzpatrick
Journal:  Front Neurosci       Date:  2017-10-23       Impact factor: 4.677

Review 10.  The importance of electrode location in cochlear implantation.

Authors:  Brendan P O'Connell; Jacob B Hunter; George B Wanna
Journal:  Laryngoscope Investig Otolaryngol       Date:  2016-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.