Literature DB >> 26944904

Efficacy of chlorine dioxide disinfection to non-fermentative Gram-negative bacilli and non-tuberculous mycobacteria in a hospital water system.

M-S Hsu1, M-Y Wu2, Y-T Huang1, C-H Liao3.   

Abstract

BACKGROUND: Chlorinated tap water in hospitals often contains low levels of non-fermentative Gram-negative bacilli (NFGNB) and non-tuberculous mycobacteria (NTM). Measures are needed to ensure a safe water supply in hospitals to prevent nosocomial infections from these waterborne pathogens. AIM: To evaluate the efficacy of ClO2 treatment of a hospital water system on the levels of NFGNB and NTM in the water.
METHODS: Our institution is a 1000-bed medical centre with two main buildings (B1 and B2). B1 has three intensive care units (ICUs) and transplant wards and polyethylene water pipes. B2 (control) has no ICUs and galvanized water pipes. A ClO2 generating unit was installed in the water system of B1 in April 2012 and water samples were collected in B1 and B2 before and eight times after installation. All samples were cultured for NFGNB and NTM.
FINDINGS: The ClO2 concentration was significantly lower in the hot water than in the cold water (P<0.001). After 40 weeks of ClO2 use, the overall NFGNB colonies decreased significantly (hot water: 160±143 vs 2±4cfu/mL, P<0.001; cold water: 108±138 vs 3±7cfu/mL, P<0.001). Highly prevalent nosocomial NFGNB, such as Pseudomonas spp. and Stenotrophomonas spp., were undetected three months after ClO2 disinfection; Sphingomonas spp. persisted but had lower colony counts. NTM was present in 25% (three out of 12) of sampling locations initially, but was not detected at two weeks after ClO2 disinfection. The ICUs had no overall change in the number of NFGNB nosocomial infections after the intervention.
CONCLUSION: Addition of a ClO2 disinfection unit to our hospital water system reduced the numbers of NTM and NFGNB in the hot and cold water systems.
Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chlorine dioxide; Non-fermentative Gram-negative bacilli; Non-tuberculous mycobacteria; Water disinfection

Mesh:

Substances:

Year:  2016        PMID: 26944904     DOI: 10.1016/j.jhin.2016.01.005

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  4 in total

Review 1.  Antibacterial Metallic Touch Surfaces.

Authors:  Victor M Villapún; Lynn G Dover; Andrew Cross; Sergio González
Journal:  Materials (Basel)       Date:  2016-08-29       Impact factor: 3.623

2.  Efficacy and Safety Evaluation of a Chlorine Dioxide Solution.

Authors:  Jui-Wen Ma; Bin-Syuan Huang; Chu-Wei Hsu; Chun-Wei Peng; Ming-Long Cheng; Jung-Yie Kao; Tzong-Der Way; Hao-Chang Yin; Shan-Shue Wang
Journal:  Int J Environ Res Public Health       Date:  2017-03-22       Impact factor: 3.390

3.  Infections and outbreaks of nontuberculous mycobacteria in hospital settings.

Authors:  Angel N Desai; Rocío M Hurtado
Journal:  Curr Treat Options Infect Dis       Date:  2018-04-25

Review 4.  Disinfectants In Interventional Practices.

Authors:  Mayank Aranke; Roya Moheimani; Melissa Phuphanich; Alan D Kaye; Anh L Ngo; Omar Viswanath; Jared Herman
Journal:  Curr Pain Headache Rep       Date:  2021-03-11
  4 in total