Literature DB >> 26944668

Biomechanical Performance of Hip Labral Repair Techniques.

Onur Hapa1, F Alan Barber2, Onur Başçı3, Levent Horoz3, Fatih Ertem4, Ahmet Karakaşlı3, Hasan Havitçioğlu3.   

Abstract

PURPOSE: To determine the strength of various suture techniques and the impact of suture passer size on cyclically loaded hip labra.
METHODS: We assigned 63 bovine hip labra to 9 simple knotless suture technique groups using OrthoCord suture: (1) penetrating grasper (2.6 mm)-placed horizontal mattress, (2) penetrating grasper-placed vertical mattress, (3) SutureLasso (1.8 mm)-placed vertical mattress, (4) penetrating grasper-placed oblique repair, (5) penetrating grasper-placed vertical mattress plus radiofrequency, (6) SutureLasso-placed horizontal mattress, (7) SutureLasso-placed oblique mattress, (8) SutureLasso-placed horizontal mattress plus radiofrequency, and (9) SutureLasso-placed oblique mattress plus radiofrequency. After 20 cycles of uniaxial tensile loading (5 to 80 N), destructive testing was performed.
RESULTS: Penetrating grasper-placed horizontal mattress sutures showed lower ultimate failure loads than vertical and oblique mattress sutures (P < .05). Penetrating grasper-placed vertical mattress sutures had higher peak-to-peak displacement than SutureLasso-placed vertical mattress sutures (P = .04). SutureLasso-placed oblique mattress sutures had a higher ultimate load (P < .01) and stiffness (P = .04) than SutureLasso-placed horizontal mattress sutures. SutureLasso-placed horizontal mattress sutures had lower cyclic elongation than penetrating grasper-placed horizontal mattress sutures (P = .01) and lower ultimate load (P < .01) and stiffness than SutureLasso-placed vertical mattress sutures (P < .01). Horizontal mattress sutures with radiofrequency had a higher ultimate load (P = .02), stiffness, and cyclic elongation (P < .01) than without radiofrequency.
CONCLUSIONS: A horizontal mattress hip labrum stitch shows a lower ultimate failure load than vertical or oblique mattress stitches. Smaller-diameter suture-passing devices show less cyclic displacement and elongation than larger-diameter devices. Radiofrequency labral treatment does not alter vertical stitch strength but does alter horizontal mattress stitch strength. CLINICAL RELEVANCE: Vertical and oblique stitches are stronger than horizontal stitches. A 1.8-mm passing device shows a better cyclic loading performance than a 2.6-mm device.
Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26944668     DOI: 10.1016/j.arthro.2015.12.044

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  1 in total

1.  Hip arthroscopy for femoroacetabular impingement.

Authors:  Rima Nasser; Benjamin Domb
Journal:  EFORT Open Rev       Date:  2018-04-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.