Literature DB >> 26940399

Occupational contact allergy to components of polyester resin systems.

Kristiina Aalto-Korte1, Katri Suuronen1.   

Abstract

BACKGROUND: Allergic contact dermatitis caused by polyester resin is considered to be rare.
OBJECTIVES: To describe 11 new patients diagnosed with occupational contact allergy to components of polyester resin systems in 1994-2009.
METHODS: Data on occupations, patch test results, symptoms and exposure to polyester products were retrieved from patient files, covering 1994 to February 2015.
RESULTS: Five patients reacted to unsaturated polyester resin putties. In 3 of these cases, putties were considered to be the main cause of the dermatitis. Four patients had cobalt allergy resulting from cobalt salts that were used as accelerators in polyester resins. Three patients were sensitized to triglycidyl isocyanurate (TGIC), a cross-linker in polyester powder paints.
CONCLUSIONS: Two product types are of particular importance in contact allergy to polyester resin: powder paints cured by heat with TGIC as the cross-linker, and car putties. Car putties are used not only in repair car painting, but also in some industrial trades to smoothen surfaces before painting. As commercial patch test substances of polyester resin putties are lacking, patients' own products need to be tested. Cobalt salts are used in several types of polyester resin product as accelerators, and these must be considered as a possible cause of cobalt sensitization.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  4-tert-butyl catechol; CAS no. 2451-62-9; car putties; cobalt; powder paints; triglycidyl isocyanurate

Mesh:

Substances:

Year:  2016        PMID: 26940399     DOI: 10.1111/cod.12561

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  3 in total

Review 1.  Contact Allergy: A Review of Current Problems from a Clinical Perspective.

Authors:  Wolfgang Uter; Thomas Werfel; Ian R White; Jeanne D Johansen
Journal:  Int J Environ Res Public Health       Date:  2018-05-29       Impact factor: 3.390

2.  A Tough, Water-Resistant, High Bond Strength Adhesive Derived from Soybean Meal and Flexible Hyper-Branched Aminated Starch.

Authors:  Yi Zhang; Jieyu Zhang; Mingsong Chen; Jing Luo; Sheldon Q Shi; Qiang Gao; Jianzhang Li
Journal:  Polymers (Basel)       Date:  2019-08-14       Impact factor: 4.329

3.  Determination of Triglycidyl Isocyanurate in Workplace Air.

Authors:  Anna Jeżewska; Joanna Kowalska
Journal:  Int J Environ Res Public Health       Date:  2019-11-13       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.