Literature DB >> 26938712

Comparison of Osteotome and Conventional Drilling Techniques for Primary Implant Stability: An In Vitro Study.

Ioanna N Tsolaki1, Pallavi P Tonsekar1, Babak Najafi1, Howard J Drew1, Andrew J Sullivan1, Sofia D Petrov2.   

Abstract

It may be difficult to achieve primary stability in the posterior maxilla because of poor quality and quantity of bone. Studies have shown that the osteotome technique immediately increases bone density thereby increasing primary stability. An in vitro study was conducted to compare the stability achieved by the osteotome and conventional drilling techniques in low density bone. Forty endosseous implant fixtures (n = 40) were inserted in a solid rigid polyurethane block simulating low density (D3) bone. The implants were divided into 4 groups to test 2 variables: (1) implant length (10 mm or 13 mm) and (2) preparation of osteotomy (conventional drilling or osteotome technique). Insertion torque (IT) and resonance frequency analysis (RFA) were measured for each implant. Statistical analysis using one-way ANOVA and Tukey post hoc test was done to study IT and RFA data of the 4 groups. Pearson Correlation test was used to determine the correlation between IT and RFA values of the implants. The IT and RFA values were statistically significant higher using the osteotome technique as compared to conventional drilling (P < 0.0001). Statistically significant higher values were also found for IT and RFA of 13 mm implants as compared to 10 mm implants. A significant correlation was found between insertion torque and RFA values in all 4 groups (r = 0.86, P < 0.0001). The conclusion was that the osteotome technique significantly increased primary stability.

Entities:  

Keywords:  bone density; bone quality; dental implant; drilling; in vitro; insertion torque; osteotome; primary stability; resonance frequency analysis; soft bone

Mesh:

Substances:

Year:  2016        PMID: 26938712     DOI: 10.1563/aaid-joi-D-15-00176

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  4 in total

1.  Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study.

Authors:  Hairong Huang; Daniel Wismeijer; Xianhong Shao; Gang Wu
Journal:  Ther Clin Risk Manag       Date:  2016-10-11       Impact factor: 2.423

2.  Multivariate linear regression analysis to identify general factors for quantitative predictions of implant stability quotient values.

Authors:  Hairong Huang; Zanzan Xu; Xianhong Shao; Daniel Wismeijer; Ping Sun; Jingxiao Wang; Gang Wu
Journal:  PLoS One       Date:  2017-10-30       Impact factor: 3.240

3.  An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of NanoShort Dental Implants.

Authors:  Luca Comuzzi; Giovanna Iezzi; Adriano Piattelli; Margherita Tumedei
Journal:  Polymers (Basel)       Date:  2019-06-10       Impact factor: 4.329

Review 4.  Contemporary Concepts in Osseointegration of Dental Implants: A Review.

Authors:  Chandrashekhar Pandey; Dinesh Rokaya; Bishwa Prakash Bhattarai
Journal:  Biomed Res Int       Date:  2022-06-14       Impact factor: 3.246

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.