Accelerated iterative beam angle selection in IMRT.

Mark Bangert1, Jan Unkelbach2.   

Abstract

PURPOSE: Iterative methods for beam angle selection (BAS) for intensity-modulated radiation therapy (IMRT) planning sequentially construct a beneficial ensemble of beam directions. In a naïve implementation, the nth beam is selected by adding beam orientations one-by-one from a discrete set of candidates to an existing ensemble of (n - 1) beams. The best beam orientation is identified in a time consuming process by solving the fluence map optimization (FMO) problem for every candidate beam and selecting the beam that yields the largest improvement to the objective function value. This paper evaluates two alternative methods to accelerate iterative BAS based on surrogates for the FMO objective function value.
METHODS: We suggest to select candidate beams not based on the FMO objective function value after convergence but (1) based on the objective function value after five FMO iterations of a gradient based algorithm and (2) based on a projected gradient of the FMO problem in the first iteration. The performance of the objective function surrogates is evaluated based on the resulting objective function values and dose statistics in a treatment planning study comprising three intracranial, three pancreas, and three prostate cases. Furthermore, iterative BAS is evaluated for an application in which a small number of noncoplanar beams complement a set of coplanar beam orientations. This scenario is of practical interest as noncoplanar setups may require additional attention of the treatment personnel for every couch rotation.
RESULTS: Iterative BAS relying on objective function surrogates yields similar results compared to naïve BAS with regard to the objective function values and dose statistics. At the same time, early stopping of the FMO and using the projected gradient during the first iteration enable reductions in computation time by approximately one to two orders of magnitude. With regard to the clinical delivery of noncoplanar IMRT treatments, we could show that optimized beam ensembles using only a few noncoplanar beam orientations often approach the plan quality of fully noncoplanar ensembles.
CONCLUSIONS: We conclude that iterative BAS in combination with objective function surrogates can be a viable option to implement automated BAS at clinically acceptable computation times.

Entities:  

Mesh:

Year:  2016        PMID: 26936695     DOI: 10.1118/1.4940350

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Parallel beamlet dose calculation via beamlet contexts in a distributed multi-GPU framework.

Authors:  Ryan Neph; Cheng Ouyang; John Neylon; Youming Yang; Ke Sheng
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

2.  Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases.

Authors:  Tiago Ventura; Humberto Rocha; Brigida da Costa Ferreira; Joana Dias; Maria do Carmo Lopes
Journal:  Phys Eng Sci Med       Date:  2021-10-07

Review 3.  Recent developments in non-coplanar radiotherapy.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; James L Bedford
Journal:  Br J Radiol       Date:  2019-02-01       Impact factor: 3.039

4.  Beam selection for stereotactic ablative radiotherapy using Cyberknife with multileaf collimation.

Authors:  James L Bedford; Peter Ziegenhein; Simeon Nill; Uwe Oelfke
Journal:  Med Eng Phys       Date:  2018-12-20       Impact factor: 2.242

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.