| Literature DB >> 26935470 |
Jia Liu1, Diana Ng2, James Lee3, Paul Stalley4,5, Angela Hong6.
Abstract
PURPOSE: Definitive radiotherapy is often used for chest wall desmoid tumours due to size or anatomical location. The delivery of radiotherapy is challenging due to the large size and constraints of normal surrounding structures. We compared the dosimetry of 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) to evaluate the best treatment option. METHODS AND MATERIALS: Ten consecutive patients with inoperable chest wall desmoid tumours (PTV range 416-4549 cm(3)) were selected. For each patient, 3DCRT, IMRT and VMAT plans were generated and the Conformity Index (CI), organ at risk (OAR) doses and monitor unit (MU) were evaluated. The Wilcoxon signed-rank test was used to compare dose delivered to both target and OARs.Entities:
Mesh:
Year: 2016 PMID: 26935470 PMCID: PMC4776360 DOI: 10.1186/s13014-016-0611-0
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Baseline demographics of subjects
| Patient Number | Age | Gender | Tumour location | Initial MRI Dimensions (cm) | PTV volume (cm3) |
|---|---|---|---|---|---|
| 1 | 29 | F | L anterior chest wall | 6.5 × 3.6 × 2.1 | 534 |
| 2 | 47 | M | R posterior chest wall | 10.0 × 3.5 × 5.5 | 2082 |
| 3 | 64 | M | R anterior chest wall | 6.9 × 2.6 × 3.0 | 767 |
| 4 | 34 | F | L axilla | 7.6 × 11.8 × 11.5 | 1017 |
| 5 | 34 | M | L axilla and lateral chest wall | 10.5 × 12.5 × 5.0 | 3896 |
| 6 | 22 | M | R axilla and supraclavicular fossa | 10.3 × 5.9 × 5.2 | 1303 |
| 7 | 46 | M | R anteriolateral chest wall | 15.0 × 20.0 × 6.0 | 4539 |
| 8 | 49 | M | L anterior chest wall | 8.5 × 5.6 × 6.8 | 950 |
| 9 | 41 | F | L anterior chest wall | 4.3 × 1.4 × 2.5 | 416 |
| 10 | 20 | M | L neck and supraclavicular fossa | 8.7 × 5.5 × 6.7 | 646 |
Summary of dosimetric results for PTV
| Parameter | 3DCRT | IMRT | VMAT |
| ||
|---|---|---|---|---|---|---|
| 3DCRT vs IMRT | 3DCRT vs VMAT | IMRT vs VMAT | ||||
| Minimum (Gy) | 40.0 ± 8.8 | 32.5 ± 11.2 | 30.57 ± 13.5 | 0.028 | 0.037 | 0.508 |
| Maximum (Gy) | 63.8 ± 3.0 | 67.5 ± 8.9 | 63.9 ± 2.9 | 0.203 | 0.959 | 0.333 |
| Mean (Gy) | 58.2 ± 1.9 | 57.5 ± 2.0 | 57.1 ± 1.4 | 0.092 | 0.074 | 0.878 |
| D5%(Gy) | 61.6 ± 2.2 | 60.5 ± 3.0 | 60.3 ± 2.5 | 0.169 | 0.037 | 0.859 |
| D95%(Gy) | 55.3 ± 2.8 | 53.3 ± 2.8 | 50.0 ± 8.6 | 0.203 | 0.053 | 0.114 |
| HI (D5 % -D95 % ; Gy) | 6.27 ± 2.76 | 7.20 ± 4.60 | 10.25 ± 10.42 | 0.575 | 0.386 | 0.139 |
| V95 % (%) | 95.5 ± 3.2 | 92.2 ± 7.2 | 92.5 ± 5.6 | 0.333 | 0.139 | 0.799 |
| CI | 1.35 ± 0.2 | 1.03 ± 0.13 | 0.98 ± 0.14 | 0.005 | 0.005 | 0.445 |
| MU | 313 ± 112 | 1427 ± 532 | 570 ± 285 | 0.005 | 0.432 | 0.005 |
| Beam on time (second) | 206 ± 122 | 302 ± 86 | 366 ± 164 | 0.056 | 0.005 | 0.231 |
CI Conformity index, defined as the ratio between the volume receiving at least 95 % of the prescribed dose and the volume of the PTV, HI Homogeneity index, defined as difference between the dose covering 5 % and dose covering 95 % of the PTV. P value determined using Wilcoxon matched pair rank sum test in SPSS
Summary of dosimetric results for Organs At Risk
| Parameter | Patients | Parameter | 3DCRT | IMRT | VMAT |
| ||
|---|---|---|---|---|---|---|---|---|
| 3DCRT vs IMRT | 3DCRT vs VMAT | IMRT vs VMAT | ||||||
| Heart | 10/10 | Mean (Gy) | 8.3 ± 7.6 | 5.7 ± 3.7 | 6.5 ± 4.3 | 0.074 | 0.333 | 0.093 |
| V25Gy (%) | 8.1 ± 14.3 | 3.6 ± 4.0 | 3.9 ± 4.9 | 0.310 | 0.735 | 0.917 | ||
| V30Gy (%) | 5.6 ± 10.0 | 3.9 ± 5.4 | 2.3 ± 3.5 | 0.237 | 0.735 | 0.753 | ||
| Lung | 10/10 | Mean (Gy) | 11.9 ± 7.9 | 9.4 ± 5.4 | 8.9 ± 4.5 | 0.014 | 0.017 | 0.386 |
| V20Gy (%) | 21.0 ± 18.7 | 16.2 ± 12.4 | 12.1 ± 7.5 | 0.021 | 0.028 | 0.515 | ||
| Right breast (contralateral breast) | 3/10 | Mean (Gy) | 3.3 ± 0.5 | 2.7 ± 0.5 | 3.5 ± 1.6 | 0.285 | 0.593 | 0.285 |
| V10Gy (%) | 2.6 ± 3.0 | 2.7 ± 2.4 | 5.2 ± 7.7 | 1.000 | 1.000 | 0.655 | ||
| V20Gy (%) | 1.4 ± 2.1 | 0.5 ± 0.8 | 0.4 ± 0.7 | 0.180 | 0.655 | 0.655 | ||
| Left breast (ipsilateral breast) | 3/10 | Mean (Gy) | 19.7 ± 12.7 | 11.4 ± 6.8 | 11.1 ± 7.6 | 0.109 | 0.109 | 0.593 |
| V10Gy (%) | 44.4 ± 36.2 | 38.9 ± 31.6 | 28.8 ± 20.4 | 0.180 | 0.285 | 0.593 | ||
| V20Gy (%) | 28.9 ± 20.0 | 18.2 ± 13.6 | 15.7 ± 18.4 | 0.285 | 0.593 | 0.593 | ||
Mean (Gy) refers to the mean dose to organ at risk. V25Gy (%) refers to the percentage of the volume receiving 25 Gy dose. P value determined using Wilcoxon matched pair rank sum test in SPSS
Fig. 1Mean Dose Volume Histograms for OAR
Fig. 2Example of dose distributions for example case for VMAT (A), IMRT (B) and 3DCRT (C)