Regeneration of a thiolated and antibody functionalized GaAs (001) surface using wet chemical processes.

Vivien Lacour1, Céline Elie-Caille2, Thérèse Leblois2, Jan J Dubowski3.   

Abstract

Wet chemical processes were investigated to remove alkanethiol self-assembled monolayers (SAMs) and regenerate GaAs (001) samples studied in the context of the development of reusable devices for biosensing applications. The authors focused on 16-mercaptohexadecanoic acid (MHDA) SAMs that are commonly used to produce an interface between antibodies or others proteins and metallic or semiconductor substrates. As determined by Fourier transform infrared absorption spectroscopy, among the investigated solutions of HCl, H2O2, and NH4OH, the highest efficiency in removing alkanethiol SAM from GaAs was shown by NH4OH:H2O2 (3:1 volume ratio) diluted in H2O. The authors observed that this result was related to chemical etching of GaAs that even in a weak solution of NH4OH:H2O2:H2O (3:1:100) proceeded at a rate of 130 nm/min. The surface revealed by a 2-min etching under these conditions allowed depositing successfully a new MHDA SAM with comparable quality and density to the initial coating. This work provides an important view on the perspective of the development of a family of cost-effective GaAs-based biosensors designed for repetitive detection of a variety of biomolecules immobilized with dedicated antibody architectures.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26934871     DOI: 10.1116/1.4942878

Source DB:  PubMed          Journal:  Biointerphases        ISSN: 1559-4106            Impact factor:   2.456


  4 in total

1.  Microfluidics for High Pressure: Integration on GaAs Acoustic Biosensors with a Leakage-Free PDMS Based on Bonding Technology.

Authors:  Saber Hammami; Aleksandr Oseev; Sylwester Bargiel; Rabah Zeggari; Céline Elie-Caille; Thérèse Leblois
Journal:  Micromachines (Basel)       Date:  2022-05-11       Impact factor: 3.523

2.  Short Ligand, Cysteine-Modified Warnericin RK Antimicrobial Peptides Favor Highly Sensitive Detection of Legionella pneumophila.

Authors:  M Amirul Islam; Walid M Hassen; Azam F Tayabali; Jan J Dubowski
Journal:  ACS Omega       Date:  2021-01-06

3.  Selective Detection of Legionella pneumophila Serogroup 1 and 5 with a Digital Photocorrosion Biosensor Using Antimicrobial Peptide-Antibody Sandwich Strategy.

Authors:  M Amirul Islam; Walid M Hassen; Ishika Ishika; Azam F Tayabali; Jan J Dubowski
Journal:  Biosensors (Basel)       Date:  2022-02-09

4.  Regenerable ZnO/GaAs Bulk Acoustic Wave Biosensor for Detection of Escherichia coli in "Complex" Biological Medium.

Authors:  Juliana Chawich; Walid M Hassen; Céline Elie-Caille; Thérèse Leblois; Jan J Dubowski
Journal:  Biosensors (Basel)       Date:  2021-05-07