Literature DB >> 26930000

A preclinical simulated dataset of S-values and investigation of the impact of rescaled organ masses using the MOBY phantom.

Theodora Kostou1, Panagiotis Papadimitroulas, George Loudos, George C Kagadis.   

Abstract

Nuclear medicine and radiation therapy, although well established, are still rapidly evolving, by exploiting animal models, aiming to define precise dosimetry in molecular imaging protocols. The purpose of the present study was to create a dataset based on the MOBY phantom for the calculation of organ-to-organ S-values of commonly used radionuclides. S-values of most crucial organs were calculated using specific biodistributions with a whole-body heterogeneous source. In order to determine the impact of the varying organs' size on the S-values, and based on the fact that the anatomic properties of the organs are correlated with S-values, dosimetric calculations were performed by simulating the MOBY-version 2 model with different whole-body masses. The GATE Monte Carlo simulation toolkit was used for all simulations. Two mouse models of different body masses were developed to calculate the S-values of eight commonly used radioisotopes in nuclear imaging studies, namely (18)F, (68)Ga, (131)I, (111)In, (177)Lu, and (99m)Tc, (90)Y and (188)Re. The impact of modified mass of the source organs in S-values was investigated with (18)F, and (90)Y in five different scalings of the source organs. Based on realistic preclinical exams, three mouse models, 22, 28 and 34 g, were used as input in the GATE simulator based on realistic preclinical exams to calculate the S-values of the six radioisotopes used. Whole body activity distributions were used as the source organ. The simulation procedure was validated in terms of extracting individual organ-to-organ S-values, and consequently in calculating the new S-values using a heterogeneous activity distribution as a source. The calculation was validated with (18)F source in a 30 g mouse model. For the generation of the new S-values with heterogeneous activity sources, four organs were used for the calculation of a single S-value. The absorbed doses per organ were compared with previously published reports. The validation procedure of (18)F indicates discrepancies, ranging from 5.32 to 7.72%. The S-values in Gy/(Bq·s), with the corresponding uncertainties of all simulated cases, are given in the developed dataset. The comparison of the dosimetric calculations on the three different phantoms highlights the impact of the mouse model size on the calculated S-values. The developed dataset can be used to improve the accuracy of the absorbed dose calculations in small animal dosimetry and depict the crucial impact the mouse size has on S-values' calculation. The generated S-values dataset for different radiopharmaceuticals contributes to the estimation of radiation dose to mice in small animal PET and SPECT exams. Finally, the detailed methodology of the procedure is provided.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26930000     DOI: 10.1088/0031-9155/61/6/2333

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  PARaDIM: A PHITS-Based Monte Carlo Tool for Internal Dosimetry with Tetrahedral Mesh Computational Phantoms.

Authors:  Lukas M Carter; Troy M Crawford; Tatsuhiko Sato; Takuya Furuta; Chansoo Choi; Chan Hyeong Kim; Justin L Brown; Wesley E Bolch; Pat B Zanzonico; Jason S Lewis
Journal:  J Nucl Med       Date:  2019-06-14       Impact factor: 10.057

2.  Murine-specific Internal Dosimetry for Preclinical Investigations of Imaging and Therapeutic Agents.

Authors:  Bryan Bednarz; Joseph Grudzinski; Ian Marsh; Abby Besemer; Dana Baiu; Jamey Weichert; Mario Otto
Journal:  Health Phys       Date:  2018-04       Impact factor: 1.316

Review 3.  Preclinical Voxel-Based Dosimetry in Theranostics: a Review.

Authors:  Arun Gupta; Min Sun Lee; Joong Hyun Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2020-04-19

4.  Pre-clinical quantitative imaging and mouse-specific dosimetry for 111In-labelled radiotracers.

Authors:  Ana M Denis-Bacelar; Sarah E Cronin; Chiara Da Pieve; Rowena L Paul; Sue A Eccles; Terence J Spinks; Carol Box; Adrian Hall; Jane K Sosabowski; Gabriela Kramer-Marek; Glenn D Flux
Journal:  EJNMMI Res       Date:  2016-11-25       Impact factor: 3.138

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.