Literature DB >> 26928874

Comprehensive untargeted lipidomic analysis using core-shell C30 particle column and high field orbitrap mass spectrometer.

Mónica Narváez-Rivas1, Qibin Zhang2.   

Abstract

The goal of untargeted lipidomics is to have high throughput, yet comprehensive and unambiguous identification and quantification of lipids. Novel stationary phases in LC separation and new mass spectrometric instruments capable of high mass resolving power and faster scanning rate are essential to achieving this goal. In this work, 4 reversed phase LC columns coupled with a high field quadrupole orbitrap mass spectrometer (Q Exactive HF) were thoroughly compared using complex lipid standard mixture and rat plasma and liver samples. A good separation of all lipids was achieved in 24min of gradient. The columns compared include C30 and C18 functionalization on either core-shell or totally porous silica particles, with size ranging from 1.7 to 2.6μm. Accucore C30 column showed the narrowest peaks and highest theoretical plate number, and excellent peak capacity and retention time reproducibility (<1% standard deviation). As a result, it resulted in 430 lipid species identified from rat plasma and rat liver samples with highest confidence. The high resolution offered by the up-front RPLC allowed discrimination of cis/trans isomeric lipid species, and the high field orbitrap mass spectrometer afforded the clear distinction of isobaric lipid species in full scan MS and the unambiguous assignment of sn-positional isomers for lysophospholipids in MS/MS. Taken together, the high efficiency LC separation and high mass resolving MS analysis are very promising tools for untargeted lipidomics analysis.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Accucore C30 column; LipidSearch; Lipidomics; Mass spectrometry; Q Exactive HF; Reverse-phase liquid chromatography; Untargeted analysis

Mesh:

Substances:

Year:  2016        PMID: 26928874      PMCID: PMC4792668          DOI: 10.1016/j.chroma.2016.02.054

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  37 in total

Review 1.  Structure and function of sphingolipid- and cholesterol-rich membrane rafts.

Authors:  D A Brown; E London
Journal:  J Biol Chem       Date:  2000-06-09       Impact factor: 5.157

2.  Identification of isobaric lyso-phosphatidylcholines in lipid extracts of gilthead sea bream (Sparus aurata) fillets by hydrophilic interaction liquid chromatography coupled to high-resolution Fourier-transform mass spectrometry.

Authors:  Sara Granafei; Ilario Losito; Francesco Palmisano; Tommaso R I Cataldi
Journal:  Anal Bioanal Chem       Date:  2015-05-03       Impact factor: 4.142

3.  Profiling of regioisomeric triacylglycerols in edible oils by supercritical fluid chromatography/tandem mass spectrometry.

Authors:  Jae Won Lee; Toshiharu Nagai; Naohiro Gotoh; Eiichiro Fukusaki; Takeshi Bamba
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-02-03       Impact factor: 3.205

4.  Separation of cis-trans phospholipid isomers using reversed phase LC with high resolution MS detection.

Authors:  Susan S Bird; Vasant R Marur; Irina G Stavrovskaya; Bruce S Kristal
Journal:  Anal Chem       Date:  2012-06-12       Impact factor: 6.986

5.  Lipidomic differentiation between human kidney tumors and surrounding normal tissues using HILIC-HPLC/ESI-MS and multivariate data analysis.

Authors:  Eva Cífková; Michal Holčapek; Miroslav Lísa; David Vrána; Bohuslav Melichar; Vladimír Študent
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-07-13       Impact factor: 3.205

6.  Simultaneous determination of molecular species of monoacylglycerols, diacylglycerols and triacylglycerols in human very-low-density lipoproteins by reversed-phase liquid chromatography.

Authors:  Javier S Perona; Valentina Ruiz-Gutierrez
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2003-02-25       Impact factor: 3.205

Review 7.  Electrospray mass spectrometry of phospholipids.

Authors:  Melissa Pulfer; Robert C Murphy
Journal:  Mass Spectrom Rev       Date:  2003 Sep-Oct       Impact factor: 10.946

8.  Enhanced lipid isomer separation in human plasma using reversed-phase UPLC with ion-mobility/high-resolution MS detection.

Authors:  Carola W N Damen; Giorgis Isaac; James Langridge; Thomas Hankemeier; Rob J Vreeken
Journal:  J Lipid Res       Date:  2014-06-02       Impact factor: 5.922

9.  The Q Exactive HF, a Benchtop mass spectrometer with a pre-filter, high-performance quadrupole and an ultra-high-field Orbitrap analyzer.

Authors:  Richard Alexander Scheltema; Jan-Peter Hauschild; Oliver Lange; Daniel Hornburg; Eduard Denisov; Eugen Damoc; Andreas Kuehn; Alexander Makarov; Matthias Mann
Journal:  Mol Cell Proteomics       Date:  2014-10-30       Impact factor: 5.911

10.  Accurate quantification of lipid species by electrospray ionization mass spectrometry - Meet a key challenge in lipidomics.

Authors:  Kui Yang; Xianlin Han
Journal:  Metabolites       Date:  2011-11-11
View more
  32 in total

1.  Off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry to improve coverage in lipidomics analysis.

Authors:  Mónica Narváez-Rivas; Ngoc Vu; Guan-Yuan Chen; Qibin Zhang
Journal:  Anal Chim Acta       Date:  2016-12-10       Impact factor: 6.558

2.  Ozone-induced dissociation on a traveling wave high-resolution mass spectrometer for determination of double-bond position in lipids.

Authors:  Ngoc Vu; Jeffery Brown; Kevin Giles; Qibin Zhang
Journal:  Rapid Commun Mass Spectrom       Date:  2017-09-15       Impact factor: 2.419

3.  Probing the Global Cellular Responses to Lipotoxicity Caused by Saturated Fatty Acids.

Authors:  Manuele Piccolis; Laura M Bond; Martin Kampmann; Pamela Pulimeno; Chandramohan Chitraju; Christina B K Jayson; Laura P Vaites; Sebastian Boland; Zon Weng Lai; Katlyn R Gabriel; Shane D Elliott; Joao A Paulo; J Wade Harper; Jonathan S Weissman; Tobias C Walther; Robert V Farese
Journal:  Mol Cell       Date:  2019-03-04       Impact factor: 17.970

4.  Liquid chromatography above 20,000 PSI.

Authors:  Matthew J Sorensen; Brady G Anderson; Robert T Kennedy
Journal:  Trends Analyt Chem       Date:  2020-01-21       Impact factor: 12.296

5.  Brain endothelial specific gene therapy improves experimental Sandhoff disease.

Authors:  Godwin Dogbevia; Hanna Grasshoff; Alaa Othman; Anke Penno; Markus Schwaninger
Journal:  J Cereb Blood Flow Metab       Date:  2019-07-29       Impact factor: 6.200

6.  A relative quantitative positive/negative ion switching method for untargeted lipidomics via high resolution LC-MS/MS from any biological source.

Authors:  Susanne B Breitkopf; Stéphane J H Ricoult; Min Yuan; Ying Xu; David A Peake; Brendan D Manning; John M Asara
Journal:  Metabolomics       Date:  2017-02-07       Impact factor: 4.290

7.  Hepatocyte Deletion of Triglyceride-Synthesis Enzyme Acyl CoA: Diacylglycerol Acyltransferase 2 Reduces Steatosis Without Increasing Inflammation or Fibrosis in Mice.

Authors:  Nina L Gluchowski; Katlyn R Gabriel; Chandramohan Chitraju; Roderick T Bronson; Niklas Mejhert; Sebastian Boland; Kun Wang; Zon Weng Lai; Robert V Farese; Tobias C Walther
Journal:  Hepatology       Date:  2019-06-26       Impact factor: 17.425

8.  Lipidomic analyses reveal enhanced lipolysis in planthoppers feeding on resistant host plants.

Authors:  Xiaohong Zheng; Yeyun Xin; Yaxin Peng; Junhan Shan; Ning Zhang; Di Wu; Jianping Guo; Jin Huang; Wei Guan; Shaojie Shi; Cong Zhou; Rongzhi Chen; Bo Du; Lili Zhu; Fang Yang; Xiqin Fu; Longping Yuan; Guangcun He
Journal:  Sci China Life Sci       Date:  2020-11-05       Impact factor: 6.038

9.  Localization of Double Bonds in Bacterial Glycerophospholipids Using 193 nm Ultraviolet Photodissociation in the Negative Mode.

Authors:  Dustin R Klein; Molly S Blevins; Luis A Macias; Martin V Douglass; M Stephen Trent; Jennifer S Brodbelt
Journal:  Anal Chem       Date:  2020-04-07       Impact factor: 6.986

10.  Accurate mass and retention time library of serum lipids for type 1 diabetes research.

Authors:  Ngoc Vu; Monica Narvaez-Rivas; Guan-Yuan Chen; Marian J Rewers; Qibin Zhang
Journal:  Anal Bioanal Chem       Date:  2019-07-06       Impact factor: 4.478

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.