Literature DB >> 26924893

Depletion of cells and abundant proteins from biological samples by enhanced dielectrophoresis.

M Javanmard1, S Emaminejad1,2, C Gupta2, J Provine2, R W Davis1, R T Howe2.   

Abstract

Platforms that are sensitive and specific enough to assay low-abundance protein biomarkers, in a high throughput multiplex format, within a complex biological fluid specimen, are necessary to enable protein biomarker based diagnostics for diseases such as cancer. The signal from an assay for a low-abundance protein biomarker in a biological fluid sample like blood is typically buried in a background that arises from the presence of blood cells and from high-abundance proteins that make up 90% of the assayed protein mass. We present an automated on-chip platform for the depletion of cells and highly abundant serum proteins in blood. Our platform consists of two components, the first of which is a microfluidic mixer that mixes beads containing antibodies against the highly abundant proteins in the whole blood. This complex mixture (consisting of beads, cells, and serum proteins) is then injected into the second component of our microfluidic platform, which comprises a filter trench to capture all the cells and the beads. The size-based trapping of the cells and beads into the filter trench is significantly enhanced by leveraging additional negative dielectrophoretic forces to push the micron sized particles (cells and beads which have captured the highly abundant proteins) down into the trench, allowing the serum proteins of lower abundance to flow through. In general, dielectrophoresis using bare electrodes is incapable of producing forces beyond the low piconewton range that tend to be insufficient for separation applications. However, by using electrodes passivated with atomic layer deposition, we demonstrate the application of enhanced negative DEP electrodes together with size-based flltration induced by the filter trench, to deplete 100% of the micron sized particles in the mixture.

Entities:  

Keywords:  Cell depletion; Dielectrophoresis; Microfluidics; Particle actuation; Sample preparation

Year:  2014        PMID: 26924893      PMCID: PMC4765371          DOI: 10.1016/j.snb.2013.11.100

Source DB:  PubMed          Journal:  Sens Actuators B Chem        ISSN: 0925-4005            Impact factor:   7.460


  35 in total

1.  Chaotic mixer for microchannels.

Authors:  Abraham D Stroock; Stephan K W Dertinger; Armand Ajdari; Igor Mezic; Howard A Stone; George M Whitesides
Journal:  Science       Date:  2002-01-25       Impact factor: 47.728

Review 2.  Protein microarrays and proteomics.

Authors:  Gavin MacBeath
Journal:  Nat Genet       Date:  2002-12       Impact factor: 38.330

3.  Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS).

Authors:  Ivan K Dimov; Lourdes Basabe-Desmonts; Jose L Garcia-Cordero; Benjamin M Ross; Younggeun Park; Antonio J Ricco; Luke P Lee
Journal:  Lab Chip       Date:  2010-12-08       Impact factor: 6.799

4.  High-throughput positive-dielectrophoretic bioparticle microconcentrator.

Authors:  Nitzan Gadish; Joel Voldman
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

5.  On-chip coupling of isoelectric focusing and free solution electrophoresis for multidimensional separations.

Authors:  Amy E Herr; Joshua I Molho; Katerina A Drouvalakis; James C Mikkelsen; Paul J Utz; Juan G Santiago; Thomas W Kenny
Journal:  Anal Chem       Date:  2003-03-01       Impact factor: 6.986

6.  Imaging and quantification of isotachophoresis zones using nonfocusing fluorescent tracers.

Authors:  Robert D Chambers; Juan G Santiago
Journal:  Anal Chem       Date:  2009-04-15       Impact factor: 6.986

7.  Nanoelectronic impedance detection of target cells.

Authors:  Rahim Esfandyarpour; Mehdi Javanmard; Zahra Koochak; James S Harris; Ronald W Davis
Journal:  Biotechnol Bioeng       Date:  2013-12-28       Impact factor: 4.530

8.  Method for analyte identification using isotachophoresis and a fluorescent carrier ampholyte assay.

Authors:  M Bercovici; G V Kaigala; J G Santiago
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

9.  Compact adaptive-grid scheme for high numerical resolution simulations of isotachophoresis.

Authors:  Moran Bercovici; Sanjiva K Lele; Juan G Santiago
Journal:  J Chromatogr A       Date:  2009-12-01       Impact factor: 4.759

10.  Dielectrophoresis as a tool to characterize and differentiate isogenic mutants of Escherichia coli.

Authors:  M Castellarnau; A Errachid; C Madrid; A Juárez; J Samitier
Journal:  Biophys J       Date:  2006-09-01       Impact factor: 4.033

View more
  3 in total

1.  Study on non-bioparticles and Staphylococcus aureus by dielectrophoresis.

Authors:  Qiaoying Chen; Zhongqing Cao; Yong J Yuan
Journal:  RSC Adv       Date:  2020-01-15       Impact factor: 4.036

2.  High-Efficiency Plasma Separator Based on Immunocapture and Filtration.

Authors:  Xiaosong Su; Jianzhong Zhang; Dongxu Zhang; Yingbin Wang; Mengyuan Chen; Zhenyu Weng; Jin Wang; Juntian Zeng; Ya Zhang; Shiyin Zhang; Shengxiang Ge; Jun Zhang; Ningshao Xia
Journal:  Micromachines (Basel)       Date:  2020-03-28       Impact factor: 2.891

3.  On-chip manufacturing of synthetic proteins for point-of-care therapeutics.

Authors:  Travis W Murphy; Jiayuan Sheng; Lynette B Naler; Xueyang Feng; Chang Lu
Journal:  Microsyst Nanoeng       Date:  2019-03-25       Impact factor: 7.127

  3 in total