High-resolution peripheral quantitative computed tomography (HR-pQCT) can assess microstructural and biomechanical properties of both human distal radius and tibia: Ex vivo computational and experimental validations.

Bin Zhou1, Ji Wang1, Y Eric Yu1, Zhendong Zhang2, Shashank Nawathe3, Kyle K Nishiyama4, Fernando Rey Rosete4, Tony M Keaveny3, Elizabeth Shane4, X Edward Guo5.   

Abstract

High-resolution peripheral quantitative computed tomography (HR-pQCT) provides in vivo three-dimensional (3D) imaging at the distal radius and tibia and has been increasingly used to characterize cortical and trabecular bone morphology in clinical studies. In this study, we comprehensively examined the accuracy of HR-pQCT and HR-pQCT based micro finite element (μFE) analysis predicted bone elastic stiffness and strength through comparisons with gold-standard micro computed tomography (μCT) based morphological/μFE measures and direct mechanical testing results. Twenty-six sets of human cadaveric distal radius and tibia segments were imaged by HR-pQCT and μCT. Microstructural analyses were performed for the registered HR-pQCT and μCT images. Bone stiffness and yield strength were determined by both HR-pQCT and μCT based linear and nonlinear μFE predictions and mechanical testing. Our results suggested that strong and significant correlations existed between the HR-pQCT standard, model-independent and corresponding μCT measurements. HR-pQCT based nonlinear μFE overestimated stiffness and yield strength while the linear μFE underestimated yield strength, but both were strongly correlated with those predicted by μCT μFE and measured by mechanical testing at both radius and tibia (R(2)>0.9). The microstructural differences between HR-pQCT and μCT were also examined by the Bland-Altman plots. Our results showed HR-pQCT morphological measurements of BV/TV(d), Tb.Th, and Tb.Sp, can be adjusted by correction values to approach true values measured by gold-standard μCT. In addition, we observed moderate correlations of HR-pQCT biomechanical and microstructural parameters between the distal radius and tibia. We concluded that morphological and mechanical properties of human radius and tibia bone can be assessed by HR-pQCT based measures.
Copyright © 2016. Published by Elsevier Inc.

Entities:  

Keywords:  Finite element analysis; HR-pQCT; Mechanical testing; μCT

Mesh:

Year:  2016        PMID: 26924718     DOI: 10.1016/j.bone.2016.02.016

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  9 in total

Review 1.  Clinical Evaluation of Bone Strength and Fracture Risk.

Authors:  Chantal M J de Bakker; Wei-Ju Tseng; Yihan Li; Hongbo Zhao; X Sherry Liu
Journal:  Curr Osteoporos Rep       Date:  2017-02       Impact factor: 5.096

Review 2.  Parathyroid Hormone-Related Changes of Bone Structure.

Authors:  M Kužma; P Jackuliak; Z Killinger; J Payer
Journal:  Physiol Res       Date:  2021-11-30       Impact factor: 1.881

3.  Gait speed and spasticity are independently associated with estimated failure load in the distal tibia after stroke: an HR-pQCT study.

Authors:  Tiev Miller; Ling Qin; Vivian W Y Hung; Michael T C Ying; Charlotte S L Tsang; Huixi Ouyang; Raymond C K Chung; Marco Y C Pang
Journal:  Osteoporos Int       Date:  2021-10-12       Impact factor: 4.507

4.  Computed Tomography-Based Stiffness Measures of Trabecular Bone Microstructure: Cadaveric Validation and In Vivo Application.

Authors:  Indranil Guha; Xialiou Zhang; Chamith S Rajapakse; Elena M Letuchy; Gregory Chang; Kathleen F Janz; James C Torner; Steven M Levy; Punam K Saha
Journal:  JBMR Plus       Date:  2022-05-05

5.  Optical bone densitometry robust to variation of soft tissue using machine learning techniques: validation by Monte Carlo simulation.

Authors:  Kaname Miura; Anak Khantachawana; Shigeo M Tanaka
Journal:  J Biomed Opt       Date:  2022-05       Impact factor: 3.758

6.  Accurate and Efficient Plate and Rod Micro Finite Element Whole Bone Models Based on High-Resolution Peripheral Computed Tomography.

Authors:  Ji Wang; Bin Zhou; Yizhong Hu; Zhendong Zhang; Y Eric Yu; Shashank Nawathe; Kyle K Nishiyama; Tony M Keaveny; Elizabeth Shane; X Edward Guo
Journal:  J Biomech Eng       Date:  2019-01-31       Impact factor: 2.097

7.  Age-related changes in size, bone microarchitecture and volumetric bone mineral density of the mandible in the harbor seal (Phoca vitulina).

Authors:  Patricia Kahle; Tim Rolvien; Horst Kierdorf; Anna Roos; Ursula Siebert; Uwe Kierdorf
Journal:  PLoS One       Date:  2019-10-24       Impact factor: 3.240

8.  Efficient materially nonlinear [Formula: see text]FE solver for simulations of trabecular bone failure.

Authors:  Monika Stipsitz; Philippe K Zysset; Dieter H Pahr
Journal:  Biomech Model Mechanobiol       Date:  2019-11-20

Review 9.  Image-based biomechanical models of the musculoskeletal system.

Authors:  Fabio Galbusera; Andrea Cina; Matteo Panico; Domenico Albano; Carmelo Messina
Journal:  Eur Radiol Exp       Date:  2020-08-13