Literature DB >> 26922781

CUSTOMISATION OF A MONTE CARLO DOSIMETRY TOOL FOR DENTAL CONE-BEAM CT SYSTEMS.

A Stratis1, G Zhang2, X Lopez-Rendon3, R Jacobs3, R Bogaerts2, H Bosmans4.   

Abstract

A versatile EGSnrc Monte Carlo (MC) framework, initially designed to explicitly simulate X-ray tubes and record the output data into phase space data files, was modified towards dental cone-beam computed tomography (CBCT) dosimetric applications by introducing equivalent sources. Half value layer (HVL) measurements were conducted to specify protocol-specific energy spectra. Air kerma measurements were carried out with an ionisation chamber positioned against the X-ray tube to obtain the total filtration attenuation characteristics. The framework is applicable to bowtie and non-bowtie inherent filtrations, and it accounts for the anode heel effect and the total filtration of the tube housing. The code was adjusted to the Promax 3D Max (Planmeca, Helsinki, Finland) dental CBCT scanner. For each clinical protocol, calibration factors were produced to allow absolute MC dose calculations. The framework was validated by comparing MC calculated doses and measured doses in a cylindrical water phantom. Validation results demonstrate the reliability of the framework for dental CBCT dosimetry purposes.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Mesh:

Year:  2016        PMID: 26922781     DOI: 10.1093/rpd/ncw024

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Development of a paediatric head voxel model database for dosimetric applications.

Authors:  Andreas Stratis; Nathan Touyz; Guozhi Zhang; Reinhilde Jacobs; Ria Bogaerts; Hilde Bosmans
Journal:  Br J Radiol       Date:  2017-07-27       Impact factor: 3.039

2.  The growing concern of radiation dose in paediatric dental and maxillofacial CBCT: an easy guide for daily practice.

Authors:  Andreas Stratis; Guozhi Zhang; Reinhilde Jacobs; Ria Bogaerts; Hilde Bosmans
Journal:  Eur Radiol       Date:  2019-07-01       Impact factor: 5.315

3.  Halve the dose while maintaining image quality in paediatric Cone Beam CT.

Authors:  Anne Caroline Oenning; Ruben Pauwels; Andreas Stratis; Karla De Faria Vasconcelos; Elisabeth Tijskens; Annelore De Grauwe; Reinhilde Jacobs; Benjamin Salmon
Journal:  Sci Rep       Date:  2019-04-02       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.