Literature DB >> 26920074

Screw insertion in trabecular bone causes peri-implant bone damage.

Juri A Steiner1, Stephen J Ferguson2, G Harry van Lenthe3.   

Abstract

Secure fracture fixation is still a major challenge in orthopedic surgery, especially in osteoporotic bone. While numerous studies have investigated the effect of implant loading on the peri-implant bone after screw insertion, less focus has been put on bone damage that may occur due to the screw insertion process itself. Therefore, the aim of this study was to localize and quantify peri-implant bone damage caused by screw insertion. We used non-invasive three-dimensional micro-computed tomography to scan twenty human femoral bone cores before and after screw insertion. After image registration of the pre- and post-insertion scans, changes in the bone micro-architecture were identified and quantified. This procedure was performed for screws with a small thread size of 0.3mm (STS, N=10) and large thread size of 0.6mm (LTS, N=10). Most bone damage occurred within a 0.3mm radial distance of the screws. Further bone damage was observed up to 0.6mm and 0.9 mm radial distance from the screw, for the STS and LTS groups, respectively. While a similar amount of bone damage was found within a 0.3mm radial distance for the two screw groups, there was significantly more bone damage for the LTS group than the STS group in volumes of interest between 0.3-0.6mm and 0.6-0.9 mm. In conclusion, this is the first study to localize and quantify peri-implant bone damage caused by screw insertion based on a non-invasive, three-dimensional, micro-CT imaging technique. We demonstrated that peri-implant bone damage already occurs during screw insertion. This should be taken into consideration to further improve primary implant stability, especially in low quality osteoporotic bone. We believe that this technique could be a promising method to assess more systematically the effect of peri-implant bone damage on primary implant stability. Furthermore, including peri-implant bone damage due to screw insertion into patient-specific in silico models of implant-bone systems could improve the accuracy of these models.
Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  image registration; orthopedic; peri-implant damage; screw insertion; μCT

Mesh:

Year:  2016        PMID: 26920074     DOI: 10.1016/j.medengphy.2016.01.006

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Trabecular deformations during screw pull-out: a micro-CT study of lapine bone.

Authors:  Thomas Joffre; Per Isaksson; Philip Procter; Cecilia Persson
Journal:  Biomech Model Mechanobiol       Date:  2017-03-06

2.  Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems.

Authors:  S Xie; K Manda; P Pankaj
Journal:  Bone Joint Res       Date:  2018-11-03       Impact factor: 5.853

3.  Medially positioned plate in first metatarsophalangeal joint arthrodesis.

Authors:  Wojciech Witkowski; Leszek Kuik; Magdalena Rucka; Karol Daszkiewicz; Angela Andrzejewska; Piotr Łuczkiewicz
Journal:  PLoS One       Date:  2021-12-01       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.