Literature DB >> 26919599

Changes in pulse pressure variation and plethysmographic variability index caused by hypotension-inducing hemorrhage followed by volume replacement in isoflurane-anesthetized dogs.

Adriana V Klein, Francisco J Teixeira-Neto, Natache A Garofalo, Angie P Lagos-Carvajal, Miriely S Diniz, Diana R Becerra-Velásquez.   

Abstract

OBJECTIVE: To compare changes in pulse pressure variation (PPV) and plethysmographic variability index (PVI) induced by hemorrhage followed by volume replacement (VR) in isoflurane-anesthetized dogs. ANIMALS: 7 healthy adult dogs. PROCEDURE: Each dog was anesthetized with isoflurane and mechanically ventilated. End-tidal isoflurane concentration was adjusted to maintain mean arterial pressure (MAP) at 60 to 70 mm Hg before hemorrhage. Controlled hemorrhage was initiated and continued until the MAP decreased to 40 to 50 mm Hg, then autologous blood removed during hemorrhage was retransfused during VR. Various physiologic variables including PPV and PVI were recorded immediately before (baseline) and after controlled hemorrhage and immediately after VR.
RESULTS: Mean ± SD PPV and PVI were significantly increased from baseline after hemorrhage (PPV, 20 ± 6%; PVI, 18 ± 4%). After VR, the mean PPV (7 ± 3%) returned to a value similar to baseline, whereas the mean PVI (10 ± 3%) was significantly lower than that at baseline. Cardiac index (CI) and stroke index (SI) were significantly decreased from baseline after hemorrhage (CI, 2.07 ± 0.26 L/min/m(2); SI, 20 ± 3 mL/beat/m(2)) and returned to values similar to baseline after VR (CI, 4.25 ± 0.63 L/min/m(2); SI, 36 ± 6 mL/beat/m(2)). There was a significant positive correlation (r(2) = 0.77) between PPV and PVI after hemorrhage. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that both PPV and PVI may be useful for identification of dogs that respond to VR with increases in SI and CI (ie, dogs in the preload-dependent limb of the Frank-Starling curve).

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26919599     DOI: 10.2460/ajvr.77.3.280

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

Review 1.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

2.  Comparison of Mean Arterial Blood Pressure and Heart Rate Changes in Response to Three Different Randomized Isotonic Crystalloid Boluses in Hypotensive Anesthetized Dogs.

Authors:  Raphaël Vézina-Audette; Marta Kantyka; Giacomo Gianotti; Deborah C Silverstein
Journal:  Animals (Basel)       Date:  2022-07-11       Impact factor: 3.231

3.  Anesthesia-Associated Relative Hypovolemia: Mechanisms, Monitoring, and Treatment Considerations.

Authors:  Jessica Noel-Morgan; William W Muir
Journal:  Front Vet Sci       Date:  2018-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.