Reliability and validity of cervical position measurements in individuals with and without chronic neck pain.

Kim Dunleavy1, Joseph Neil2, Allison Tallon3, Diane E Adamo.   

Abstract

OBJECTIVES: The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures.
METHODS: (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared.
RESULTS: (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and -1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). DISCUSSION: Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test-retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles.

Entities:  

Keywords:  Cervical position; Cervical range of motion device; Cervical spine; Criterion validity; Posture; Reliability

Year:  2015        PMID: 26917936      PMCID: PMC4727731          DOI: 10.1179/2042618614Y.0000000070

Source DB:  PubMed          Journal:  J Man Manip Ther        ISSN: 1066-9817


  39 in total

1.  A field comparison of neck and shoulder postures in symptomatic and asymptomatic office workers.

Authors:  Grace P Y Szeto; Leon Straker; Sally Raine
Journal:  Appl Ergon       Date:  2002-01       Impact factor: 3.661

2.  Asymmetry in grasp force matching and sense of effort.

Authors:  Diane E Adamo; Samantha Scotland; Bernard J Martin
Journal:  Exp Brain Res       Date:  2012-01-05       Impact factor: 1.972

3.  A comparison of symptomatic and asymptomatic office workers performing monotonous keyboard work--2: neck and shoulder kinematics.

Authors:  Grace P Y Szeto; Leon M Straker; Peter B O'Sullivan
Journal:  Man Ther       Date:  2005-07-05

4.  Recruitment of the deep cervical flexor muscles during a postural-correction exercise performed in sitting.

Authors:  Deborah Falla; Shaun O'Leary; Amy Fagan; Gwendolen Jull
Journal:  Man Ther       Date:  2006-08-08

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Body posture and hand strength of patients with temporomandibular disorder.

Authors:  Y Y Shiau; H M Chai
Journal:  Cranio       Date:  1990-07       Impact factor: 2.020

Review 7.  Clinical methods for quantifying body segment posture: a literature review.

Authors:  Carole Fortin; Debbie Ehrmann Feldman; Farida Cheriet; Hubert Labelle
Journal:  Disabil Rehabil       Date:  2010-06-23       Impact factor: 3.033

8.  The feasibility of a video-based motion analysis system in measuring the segmental movements between upper and lower cervical spine.

Authors:  Shyi-Kuen Wu; Howard H C Lan; Li-Chieh Kuo; Sen-Wei Tsai; Chiung-Ling Chen; Fong-Chin Su
Journal:  Gait Posture       Date:  2006-09-20       Impact factor: 2.840

9.  Intrarater reliability of CROM measurement of cervical spine active range of motion in persons with and without neck pain.

Authors:  James P Fletcher; William D Bandy
Journal:  J Orthop Sports Phys Ther       Date:  2008-10       Impact factor: 4.751

10.  Reliability of measuring forward head posture in a clinical setting.

Authors:  T R Garrett; J W Youdas; T J Madson
Journal:  J Orthop Sports Phys Ther       Date:  1993-03       Impact factor: 4.751

View more
  5 in total

Review 1.  The Relationship Between Forward Head Posture and Neck Pain: a Systematic Review and Meta-Analysis.

Authors:  Nesreen Fawzy Mahmoud; Karima A Hassan; Salwa F Abdelmajeed; Ibraheem M Moustafa; Anabela G Silva
Journal:  Curr Rev Musculoskelet Med       Date:  2019-12

2.  Interexaminer Reliability and Validity of Quantity of Cervical Mobility during Online Dynamic Inspection.

Authors:  Leire Leonet-Tijero; Jaime Corral-de-Toro; Jacobo Rodríguez-Sanz; Mar Hernández-Secorún; Hugo Abenia-Benedí; María Orosia Lucha-López; Sofía Monti-Ballano; Julián Müller-Thyssen-Uriarte; Héctor Tricás-Vidal; César Hidalgo-García; José Miguel Tricás-Moreno
Journal:  Diagnostics (Basel)       Date:  2022-02-21

3.  Development of the circumduction metric for identification of cervical motion impairment.

Authors:  Yue Zhou; Eldon Loh; James P Dickey; David M Walton; Ana Luisa Trejos
Journal:  J Rehabil Assist Technol Eng       Date:  2018-07-25

4.  Measurements of cervical range of motion using an optical motion capture system: Repeatability and validity.

Authors:  Minshan Feng; Long Liang; Wu Sun; Guang Wei Liu; Xunlu Yin; Tao Han; Xu Wei; Liguo Zhu
Journal:  Exp Ther Med       Date:  2019-10-15       Impact factor: 2.447

5.  Psychometric Proprieties of a Mobile Application to Measure the Craniovertebral Angle a Validation and Reliability Study.

Authors:  Tomas Gallego-Izquierdo; Enrique Arroba-Díaz; Gema García-Ascoz; María Del Alba Val-Cano; Daniel Pecos-Martin; Roberto Cano-de-la-Cuerda
Journal:  Int J Environ Res Public Health       Date:  2020-09-08       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.