Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.

Bronwyn U Harris1, Danton S Char, Jeffrey A Feinstein, Archana Verma, Stephen C Shiboski, Chandra Ramamoorthy.   

Abstract

OBJECTIVES: Prior studies have shown inaccuracies in pulse oximetry readings at saturations less than 85%; however, no large studies have evaluated new sensors marketed for these low saturations. This study's purpose was to evaluate two sensors with claims of improved accuracy in children with saturations less than 85%.
DESIGN: Prospective observational study.
SETTING: Single institution; cardiac catheterization laboratory, and operating room. PATIENTS: Fifty patients weighing 3-20 kg with baseline saturations less than 90% undergoing surgical or catheterization procedure.
MEASUREMENTS AND MAIN RESULTS: Data collected included demographics, diagnosis, continuous saturations from three different pulse oximeters (Masimo LNCS [Masimo, Irvine, CA], Masimo Blue [Masimo], and Nellcor Max-I [Medtronic, Dublin, Ireland]) and up to four blood samples for co-oximetry as the gold-standard arterial oxygen saturation. Analysis included scatter plots, smoothed regression estimates of mean continuous saturation levels plotted against corresponding arterial oxygen saturation values, and Bland-Altman plots. Bland-Altman analysis indicated increasing levels of bias and variability for decreasing arterial oxygen saturation levels for all three sensors, with a statistically significant increase in mean difference observed for decreasing arterial oxygen saturation level. The Masimo Blue sensor had the lowest mean difference, SD and Bland-Altman limits in patients with saturations less than or equal to 85%. At saturation range of less than or equal to 85% and greater than 75%, 14% of the samples obtained from Masimo Blue, 24% of the readings from the Nellcor, and 31% from the Masimo Standard sensors were greater than or equal to 5% points difference. All three sensors had a further increase in these differences for arterial oxygen saturation values less than 75%.
CONCLUSIONS: The Masimo Blue sensor has improved accuracy at saturations 75-85% versus the Nellcor and Masimo Standard sensors. The accuracy of peripheral capillary oxygen saturation of the Masimo Blue sensor was within 5% points of the arterial oxygen saturation the majority of the time. Currently, at saturations less than or equal to 85%, pulse oximetry alone should not be relied on in making clinical decisions.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26914626     DOI: 10.1097/PCC.0000000000000660

Source DB:  PubMed          Journal:  Pediatr Crit Care Med        ISSN: 1529-7535            Impact factor:   3.624


  4 in total

1.  Risk Factors for Cardiac Adverse Events in Infants and Children with Complex Heart Disease Scheduled for Bi-ventricular Repair: Prognostic Value of Pre-operative B-Type Natriuretic Peptide and High-Sensitivity Troponin T.

Authors:  Yoshiki Mori; Yasumi Nakashima; Sachie Kaneko; Nao Inoue; Tomotaka Murakami
Journal:  Pediatr Cardiol       Date:  2020-08-17       Impact factor: 1.655

2.  The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis.

Authors:  Chunhu Shi; Mark Goodall; Jo Dumville; James Hill; Gill Norman; Oliver Hamer; Andrew Clegg; Caroline Leigh Watkins; George Georgiou; Alexander Hodkinson; Catherine Elizabeth Lightbody; Paul Dark; Nicky Cullum
Journal:  BMC Med       Date:  2022-08-16       Impact factor: 11.150

3.  Measuring accuracy of plethysmography based respiratory rate measurement using pulse oximeter at a tertiary hospital in India.

Authors:  Varun Alwadhi; Enisha Sarin; Praveen Kumar; Prasant Saboth; Ajay Khera; Sachin Gupta; Harish Kumar
Journal:  Pneumonia (Nathan)       Date:  2020-06-05

4.  Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings - A prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda.

Authors:  Kevin Baker; Max Petzold; Akasiima Mucunguzi; Alexandra Wharton-Smith; Emily Dantzer; Tedila Habte; Lena Matata; Diana Nanyumba; Morris Okwir; Monica Posada; Anteneh Sebsibe; Jill Nicholson; Madeleine Marasciulo; Rasa Izadnegahdar; Tobias Alfvén; Karin Källander
Journal:  EClinicalMedicine       Date:  2021-07-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.