| Literature DB >> 26913143 |
Isuru D Jayasinghe1, Alexander H Clowsley1, Michelle Munro2, Yufeng Hou2, David J Crossman2, Christian Soeller3.
Abstract
The t-tubular system plays a central role in the synchronisation of calcium signalling and excitation-contraction coupling in most striated muscle cells. Light microscopy has been used for imaging t-tubules for well over 100 years and together with electron microscopy (EM), has revealed the three-dimensional complexities of the t-system topology within cardiomyocytes and skeletal muscle fibres from a range of species. The emerging super-resolution single molecule localisation microscopy (SMLM) techniques are offering a near 10-fold improvement over the resolution of conventional fluorescence light microscopy methods, with the ability to spectrally resolve nanometre scale distributions of multiple molecular targets. In conjunction with the next generation of electron microscopy, SMLM has allowed the visualisation and quantification of intricate t-tubule morphologies within large areas of muscle cells at an unprecedented level of detail. In this paper, we review recent advancements in the t-tubule structural biology with the utility of various microscopy techniques. We outline the technical considerations in adapting SMLM to study t-tubules and its potential to further our understanding of the molecular processes that underlie the sub-micron scale structural alterations observed in a range of muscle pathologies.Entities:
Keywords: cardiac muscle; excitation-contraction coupling; horse; human; mouse; rabbit; rat; skeletal muscle; super-resolution microscopy; t-tubules
Year: 2014 PMID: 26913143 PMCID: PMC4748971 DOI: 10.4081/ejtm.2015.4747
Source DB: PubMed Journal: Eur J Transl Myol ISSN: 2037-7452
Features of localisation microscopy techniques and their advantages and limitations towards t-tubule imaging in muscles
| Features | Advantages | Limitations |
|---|---|---|
| Nanometre resolution across sub-millimetre sized areas | >10 fold improvement over diffraction-limited fluorescence techniques | Resolution is only limited by detectable light yield from a single event, size of the fluorescent label/complex and the local density of the fluorescent probes. |
| Can be performed in aqueous and non-aqueous sample environments | Compatible with correlative imaging with EM and other light microscopies | |
| Fluorophore photoswitching kinetics are adjustable | Can be modulated by excitation intensity, chemical constituents in the mounting buffer and/or a secondary activation laser. | Abbreviating the fluorophore ON time further than a few milliseconds reduces photon yield, compromising the localisation accuracy. |
| Image is generated based on localised map of fluorophore position and localisation error | Images are (in principle) quantifiable for | Quantifiability of image data hinges on accurate localisation of overlapping events and correcting for local fluorophore density dependence of repeated photoswitching or limited yieldsof the molecules. |
| Single molecule events consist of a unique spectral signature | Spectral filtering can ‘unmix’ between multiple fluorophores or autofluorescence to achieve greater specificity in visualising the target structure. | |
| Reconstructed greyscale images are “background free” | More robust binarisation of images | Any background fluorescence limits localisation accuracy (hence, resolution) |
| Ability to resolve structures in “thick” samples | Compatible with immunocytochemistry and tissue samples sectioned with standard microtomes (typically 10-20 microns in thickness) | Light scattering, spherical aberration and out of focus fluorescence typically seen in thick samples diminish the localisation accuracy. Therefore, thin samples are ideal (e.g. cultured cells). The native t-tubule structure is poorly preserved in cultured myocytes or myoblasts. |
| 3D localisation | Suitable for resolving the three-dimensional complexities of t-tubles | Thin samples (<10 microns) with dense t-tubule labelling with low background fluorescence work best. |
| Photoswitchability of endogenous, genetically encoded or introduced fluorophores in aqueous physiological saline environments | Compatible with real-time imaging t-tubules in living/functional preparations | Photodamage to the cells/fibres from prolonged intense light exposure and oxidants generated from the photoswitching (but yet to be quantified if any worse than other imaging approaches) |
Fig 1.Simulating the effect of labelling densities and background fluorescence on diffraction-limited and SMLM images. (A) A phantom t-tubule with a varying diameter (a = 130 nm and b = 280 nm) and a 20 nm-thick layer of fluorescent markers (similar to combined thickness of a layer of primary and secondary antibodies bound to a t-tubular protein; e.g. caveolin-3) is simulated in (i) confocal micrographs and (ii) typical 2D dSTORM. Images were simulated for labelling densities of (B) 0.12/nm2, typical of very high fluorophore densities, (C) 0.008/nm2, typically achieved in experimental samples and (D) 0.0005/nm2 to simulate a 15-fold poorer labelling than typical. Notice the gradual loss of detail in the dSTORM images with the diminishing labelling density and little observable difference between the confocal images (B-i & C-i). To simulate the effect of higher background intensity (E), the background intensity was set to 50% of the foregraound intensity and a foreground labelling density comparable to the simulation in panel-C. Notice the lack of detail on the dSTORM image (E-ii compared to C-ii) while little change is seen in the morphologies in the confocal images (E-i compared to C-i). Scale bar: 500 nm.
Fig 2.Confocal fluorescence microscopy of t-tubules of isolated living myocytes. (A) A whole cell longitudinal confocal image of a rat ventricular myocyte immersed in a dextran-linked fluorescein solution similar to the method used by Soeller and Cannell.[38] (B) Magnified view illustrates the membrane impermeable dextran-fluorescein entry into the t-tubules reporting local tubule geometry and volume against the dark background of the myoplasm. Note the oblique (asterisk) and longitudinal tubules (arrowheads) that are clearly visible with this approach. (C) The percentage distribution of local tubule diameter estimates from such diffraction-limited data (blue bars; Soeller & Cannell) has a similar mean to that based on dSTORM data. Note the limited measurements (poor detection) of tubule diameters that are <70 nm in the diffraction-limited analysis (arrow), while the dSTORM analysis is able to detect >2-times the fraction of tubules narrower than 70 nm. Scale bars: A: 20 µm, B: 5 µm.
Fig 3.Comparison of micron- and nanometre-scale morphologies in adult mammalian cardiac t-systems. Transverse (i) Confocal and (ii) dSTORM images blurred with a 2D Gaussian PSF equivalent to a confocal PSF (left panels) and super-resolution image (right). Shown myocytes of (A) C57-BL/6 mouse and (B) Wistar rat were stained with a combination of NCX1 and CAV3. Fixed ventricular tissue sections from (C) New Zealand White rabbit, (D) Human (54-year old donor with normal echocardiogram) and (E) Horse (12-year old female New Forest pony) were stained with fluorescent wheat germ agglutinin to visualise the t-tubules. Note the nanometre- and micron-scale t-tubule dilatations in mouse and rabbit myocytes respectively (arrowheads). Cell surface in each example is indicated by asterisks. Scale bars: i-panels: 2 µm; ii: 1 µm.
Fig 4.Visualisation of t-tubules in mammalian skeletal muscle. (A) A longitudinal confocal micrograph of a “mechanically skinned” rat extensor digitorum longus (EDL) fibre with membrane impermeable dye trapped in the t-system. (B) A dSTORM image of t-tubule organisation in the flanks of a single z-line of a similar fibre. T-tubules were filled with fixable dextran and the fibre was skinned to trap the dye prior to fixation. (C) Shown is a percentage histogram of the mean diameter of t-tubules in adult rat EDL fibres calculated by modelling the tubules as flattened cylinders. Notice the left-skewed shape of the histogram, which is a result of the poor detection efficiency of tubules with a mean diameter narrower than ~40 nm. More tubules are expected to be detected with smaller diameters (expected fractions approximated by dashed lines) with the super-resolution method. Scale bars: A: 5 µm; B: 0.5 µm.