Literature DB >> 26911298

Accuracy and evaluation of irradiation of novel localization devices with unique three-dimensional structures in microendoscopic spine surgery.

Masanari Takami1, Amr Elwany2, Jean Destandau2.   

Abstract

BACKGROUND: Although many reports are available on using a variety of instruments and techniques to prevent wrong-level spine surgery, the accurate localization of the correct spinal level remains problematic. At the same time, surgeons are also required to reduce radiation exposure to patients and operating room personnel. To solve these problems, we developed and used specially designed marking devices with a unique three-dimensional structure.
PURPOSE: To evaluate the accuracy of our novel devices for localization of the spinal level to prevent wrong-level surgery and reduce the amount and time of radiation exposure during surgery. STUDY
DESIGN: This was a retrospective cohort study.
METHODS: In 8240 consecutive patients who underwent microendoscopic spine surgery between 1993 and 2012, the incidence of wrong-level surgery was studied. In addition, the amount of radiation exposure and total fluoroscopy time were measured in recent 100 consecutive patients using a digital dosimeter attached to the fluoroscope.
RESULTS: Eight (0.097 %) patients had undergone wrong-level surgery. The average radiation exposure was 0.26 mGy (range 0.10-1.15 mGy), and the average total fluoroscopy time was 3.1 s (range 1-7 s).
CONCLUSIONS: Our novel localization devices and technique for their use in spine surgery are reliable and accurate for identifying the target level and contributed to reductions in preoperative localization error and radiation exposure to patients and operating room personnel.

Entities:  

Keywords:  Localization device; Microendoscopic surgery; Radiation exposure; Spine surgery; Wrong-level surgery

Mesh:

Year:  2016        PMID: 26911298     DOI: 10.1007/s00590-016-1747-1

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  18 in total

1.  Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

Authors:  Kisung Lee; Kyoung Min Lee; Moon Seok Park; Boram Lee; Dae Gyu Kwon; Chin Youb Chung
Journal:  Spine (Phila Pa 1976)       Date:  2012-06-15       Impact factor: 3.468

2.  Radiation exposure to the surgeon during open lumbar microdiscectomy and minimally invasive microdiscectomy: a prospective, controlled trial.

Authors:  Michael W Mariscalco; Takayuki Yamashita; Michael P Steinmetz; Ajit A Krishnaney; Isador H Lieberman; Thomas E Mroz
Journal:  Spine (Phila Pa 1976)       Date:  2011-02-01       Impact factor: 3.468

Review 3.  Avoiding wrong site surgery: a systematic review.

Authors:  John Devine; Norman Chutkan; Daniel C Norvell; Joseph R Dettori
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

4.  Minimally invasive approach to the cervical spine: a proposal.

Authors:  P Miccoli; P Berti; M Raffaelli; G Materazzi; M Conte; A Faldini
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2001-04       Impact factor: 1.878

5.  Avoidance of wrong-level thoracic spine surgery: intraoperative localization with preoperative percutaneous fiducial screw placement.

Authors:  Cheerag D Upadhyaya; Jau-Ching Wu; Cynthia T Chin; Gopalakrishnan Balamurali; Praveen V Mummaneni
Journal:  J Neurosurg Spine       Date:  2011-11-04

6.  Microsurgical and standard removal of the protruded lumbar disc: a comparative study.

Authors:  D H Wilson; R Harbaugh
Journal:  Neurosurgery       Date:  1981-04       Impact factor: 4.654

7.  Novel fluoroscopic technique for localization at cervicothoracic levels.

Authors:  Harshpal Singh; Scott A Meyer; Andrew C Hecht; Arthur L Jenkins
Journal:  J Spinal Disord Tech       Date:  2009-12

8.  Intraoperative localization of thoracic spine level with preoperative percutaneous placement of intravertebral polymethylmethacrylate.

Authors:  Wesley Hsu; Daniel M Sciubba; A Daniel Sasson; Yevgeniy Khavkin; Jean-Paul Wolinsky; Philippe Gailloud; Ziya L Gokaslan; Kieran Murphy
Journal:  J Spinal Disord Tech       Date:  2008-02

9.  Wrong-level surgery: A unique problem in spine surgery.

Authors:  John Hsiang
Journal:  Surg Neurol Int       Date:  2011-04-19

10.  Unusual spine anatomy contributing to wrong level spine surgery: a case report and recommendations for decreasing the risk of preventable 'never events'.

Authors:  Emily M Lindley; Sergiu Botolin; Evalina L Burger; Vikas V Patel
Journal:  Patient Saf Surg       Date:  2011-12-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.