| Literature DB >> 26909010 |
Aqilah Leela T Narayanan1, Syed Rasul G Syed Hamid2, Eko Supriyanto1.
Abstract
BACKGROUND: Evidence regarding the effectiveness of incentive spirometry (ISy) on postoperative pulmonary outcomes after thoracic, cardiac and abdominal surgery remains inconclusive. This is attributed to various methodological issues inherent in ISy trials. Patient compliance has also been highlighted as a possible confounding factor; however, the status of evidence regarding patient compliance in these trials is unknown.Entities:
Keywords: Abdomen; Heart surgery; Incentive, Respiratory therapy; Spirometry; Thoracic surgery
Year: 2016 PMID: 26909010 PMCID: PMC4751968
Source DB: PubMed Journal: Can J Respir Ther ISSN: 1205-9838
Figure 1)Flowchart depicting the trials retrieval process
Brief summary of reviewed articles with details regarding incentive spirometry (ISy)
|
| |||||
|---|---|---|---|---|---|
| Van De Water et al ( | Bartlett-Edwards: | Session frequency | Record of cumulative time of breath hold | Timing device attached to Bartlett-Edwards IS that records breath hold time | Data regarding total breath hold time (in seconds) for each postoperative day for 2 patients (one with and one without PPCs) |
| Craven et al ( | Bartlett-Edwards: | Session frequency | Inspiration frequency | Barlett-Edwards IS | General observation on possible association between inspiration frequency and volume achievements with development of PPCs |
| Dohi and Gold ( | Triflo: | Session frequency | Not stated | Not stated | None |
| Iverson et al ( | Not specifed: | Session frequency | Not stated | Not stated | None |
| Lyager et al ( | Bartlett-Edwards: | Session frequency | Inspiration frequency | Barlett-Edwards IS | Average inspiration frequency for whole postoperative period |
| Gale and Sanders ( | Bartlett-Edwards: | Session duration | Not stated | Supervision by respiratory therapist | None |
| Jung et al ( | Spirocare: | Session frequency | Not stated | Supervision by staff | None |
| Lederer et al ( | Triflo; Spirocare; Bartlett-Edwards: | Session frequency | Session frequency | Daily feedback from patients on frequency of use | No specific data on any ISy parameters |
| Minschaert et al ( | Respirex: | Session frequency | Not stated | Not stated | None |
| Stock et al ( | Bartlett-Edwards: | Session duration | Not stated | Supervision by physicians and therapists | None |
| Dull and Dull ( | Spirocare: | Session frequency | Not stated | Supervision by physiotherapists | None |
| Celli et al ( | Not specified: | Session frequency | Not stated | Supervision by respiratory personnel | None |
| Stock et al ( | Bartlett-Edwards: | Session duration | Inspiration frequency | Barlett-Edwards IS | Data on mean number of times 3 s breath hold achieved and mean maximal volume achieved for the 15 min sessions from POD 1 to POD 3 |
| Stock et al ( | Bartlett-Edwards: | Session duration | Inspiration frequency | Barlett-Edwards IS | Data on mean number of times 3 s breath hold achieved and mean maximal volume achieved for the 15 min sessions from POD 1 to POD 3 |
| Ricksten et al ( | Triflo: | Session frequency | Session frequency | Each hourly session noted on record sheet by nurse or patient | None |
| Schwieger et al ( | Inspiron: | Session duration | Not stated | Supervision by respiratory personnel | None |
| O’Connor et al ( | Inspiron: | Session frequency | Not stated | Not stated | None |
| Rau et al ( | Spirocare; Voldyne: | Session frequency | Not stated | Group 1 and 2 – 4 daily sessions supervised by therapist | None |
| Jenkins et al ( | Triflo: | Session frequency Inspiration frequency | Not stated | Patients’ self-reports (instructed to report frequency of sessions – 10 inspirations equals one session) | None |
| Hall et al ( | Airlife: | Session duration | General compliance levels – specific ISy parameters not stated | Assessments on compliance made by research nurse on 0–100 mm visual linear analogue scale | No specific data on any ISy parameters – only brief mention on outcomes of ‘poor compliers’ |
| Oikkonen et al ( | Coach: |
Session frequency Inspiration frequency Breath hold Flow rate | Not stated | Not stated | None |
| Hall et al ( | Airlife: | Session frequency | General compliance levels – specific ISy parameters not stated | Assessments on compliance made by research nurse on 0–100 mm visual linear analogue scale | No specific data on any ISy parameters Data available - mean compliance level for the entire postoperative period |
| Crowe et al ( | Voldyne: | Session frequency | Not stated | Patient and staff required to record use of IS on forms provided | None |
| Weiner et al ( | Coach: | Session duration | Not stated | Supervision by staff | None |
| Gosselink et al ( | Voldyne: | Session frequency | Not stated | Not stated | None |
| Matte et al ( | Coach: | Session frequency | Not stated | Not stated | None |
| Ebeo et al ( | Not specified: | Not stated | Not stated | Not stated | None |
| Savci et al ( | Not specified: | Session duration | Not stated | Not stated | None |
| Romanini et al ( | Voldyne: | Session duration | Not stated | Not stated | None |
| Haeffener et al ( | Voldyne: | Session duration | Not stated | Supervision by physiotherapists | None |
| Renault et al ( | Respiron: | Session frequency | Session frequency | Patients record on session frequency in ‘adherence’ log | Mean frequency of ISy sessions as obtained from adherence log |
| Kundra et al ( | Not specified: | Session frequency | Not stated | Feedback from patients | None |
| Cattano et al ( | Airlife: | Session frequency | Volume achievements | Log sheet for patients to record IS volume achieved in each session | No specific data on any ISy parameters |
| Kulkarni et al ( | Spiroball: | Session duration | Not stated | Not stated | None |
| Dias et al ( | Voldyne: | Session frequency | Not stated | Supervision by physiotherapists | None |
| Agostini et al ( | Coach 2: | Session frequency | Not stated | POD 1: Supervision by physiotherapists | None |
IS Incentive spirometer; POD Postoperative day; PPCs Postoperative pulmonary complications
Figure 2)Frequency of each incentive spirometry (ISy) parameter(s) prescribed versus parameter(s) assessed in the primary trials
Comparison between mean percentages of incentive spirometry parameters prescribed with parameters assessed
|
| ||
|---|---|---|
| 100 | 12.95 | <0.0001 |
Figure 3)Frequency of methods used for monitoring compliance/collecting incentive spirometry usage data in primary trials between 1972 and 2015
Figure 4)Frequency of use of incentive spirometers with and without counter features in primary trials between 1972 and 2015