Literature DB >> 26906396

Comparison of in-laboratory and home diagnosis of sleep apnea using a cordless portable acoustic device.

Hisham Alshaer1, Geoff R Fernie2, Wen-Hou Tseng3, T Douglas Bradley4.   

Abstract

BACKGROUND AND OBJECTIVES: Sleep apnea (SA) is a common, serious, but underdiagnosed condition. There is a need for more accessible and economic means of diagnosing SA in the home. The aim of this study was to test the validity of a cordless acoustic portable device (BresoDx™) for home diagnosis of SA compared with standard polysomnography (PSG).
METHODS: A total of 135 subjects underwent full overnight PSG and simultaneous recording of breath sounds by BresoDx in the sleep laboratory. Acoustic data extracted from BresoDx were analyzed using validated computer acoustic algorithms. The PSG-derived apnea-hypopnea index (AHI-p) and the acoustic AHI (AHI-a) were calculated and compared. A subset of 100 subjects used the device in a subsequent night in their home from which home AHI (AHI-h) was determined.
RESULTS: The correlation between AHI-a and simultaneous AHI-p was 95.2% and diagnostic accuracy of BresoDx ranged between 88.9% and 93.3% around AHI cutoffs of 5-15. In the home, AHI-h did not differ significantly from AHI-p (p = 0.60). Using an AHI-p cutoff ≥ 10 BresoDx's accuracy was 81%. Of the 100 subjects, 81 (81%) had low inter-night variability measured by a difference between home AHI-h and PSG AHI-p < 10 event/h, while 19% had higher inter-night variability.
CONCLUSION: AHI determined using BresoDx was in excellent agreement with simultaneous AHI-p. The majority of patients had a consistent AHI in their subsequent home study with very good overall diagnostic accuracy. We conclude that BresoDx is a reliable device for diagnosing SA that can be used by subjects, unattended in their own homes.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acoustic; Cordless portable device; Home diagnosis; Sleep apnea

Mesh:

Year:  2015        PMID: 26906396     DOI: 10.1016/j.sleep.2015.11.003

Source DB:  PubMed          Journal:  Sleep Med        ISSN: 1389-9457            Impact factor:   3.492


  7 in total

1.  Diagnostic accuracy of level IV portable sleep monitors versus polysomnography for obstructive sleep apnea: a systematic review and meta-analysis.

Authors:  Lusine Abrahamyan; Yeva Sahakyan; Suzanne Chung; Petros Pechlivanoglou; Joanna Bielecki; Steven M Carcone; Valeria E Rac; Michael Fitzpatrick; Murray Krahn
Journal:  Sleep Breath       Date:  2018-01-09       Impact factor: 2.816

2.  Influence of head position on obstructive sleep apnea severity.

Authors:  Kaiyin Zhu; T Douglas Bradley; Maryam Patel; Hisham Alshaer
Journal:  Sleep Breath       Date:  2017-06-12       Impact factor: 2.816

3.  In-hospital diagnosis of sleep apnea in stroke patients using a portable acoustic device.

Authors:  Clodagh M Ryan; Kelly Wilton; T Douglas Bradley; Hisham Alshaer
Journal:  Sleep Breath       Date:  2016-12-02       Impact factor: 2.816

4.  Long-term effects of cardiac rehabilitation on sleep apnea severity in patients with coronary artery disease.

Authors:  Monique Mendelson; Toru Inami; Owen Lyons; Hisham Alshaer; Susan Marzolini; Paul Oh; T Douglas Bradley
Journal:  J Clin Sleep Med       Date:  2019-12-03       Impact factor: 4.062

5.  Reproducibility and predictors of the apnea hypopnea index across multiple nights.

Authors:  Hisham Alshaer; Clodagh Ryan; Geoff R Fernie; T Douglas Bradley
Journal:  Sleep Sci       Date:  2018 Jan-Feb

Review 6.  Obstructive sleep apnea: transition from pathophysiology to an integrative disease model.

Authors:  Walter T McNicholas; Dirk Pevernagie
Journal:  J Sleep Res       Date:  2022-05-24       Impact factor: 5.296

7.  Screening for obstructive sleep apnea with novel hybrid acoustic smartphone app technology.

Authors:  Roxana Tiron; Graeme Lyon; Hannah Kilroy; Ahmed Osman; Nicola Kelly; Niall O'Mahony; Cesar Lopes; Sam Coffey; Stephen McMahon; Michael Wren; Kieran Conway; Niall Fox; John Costello; Redmond Shouldice; Katharina Lederer; Ingo Fietze; Thomas Penzel
Journal:  J Thorac Dis       Date:  2020-08       Impact factor: 3.005

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.