Literature DB >> 26905258

Electrooxidation of New Synthetic Cannabinoids: Voltammetric Determination of Drugs in Seized Street Samples and Artificial Saliva.

Marina Dronova1, Evgeny Smolianitski1, Ovadia Lev1.   

Abstract

The electrochemical sensing of new psychoactive substances, synthetic cannabinoids (SCs), commonly marketed under the trade name "Spice" is explored for the first time. The electrooxidative transformations of 11 new indole and indazole SCs which are currently the predominant illicit smoking mixtures on the drug market is performed using cyclic and differential pulse voltammetry with various commercially available electrodes (Pt, GC, Bdd). It is found that SCs exhibit voltammetric responses that can be used for their detection in smoking mixtures and artificial saliva with limits of detection in the nanomolar range. The indole-based SCs exhibited an anodic peak at ∼1.5 V (vs Ag/Ag(+)) and ∼1.2 V (vs Ag/AgCl) in acetonitrile and artificial saliva, respectively, and the indazoles exhibited corresponding peaks at ∼1.7 V and ∼1.5 V. The voltammetric procedure was evaluated by prescreening of SCs in 12 confiscated street samples that were also independently analyzed by GC-MS and LC-MS techniques. A good agreement between the three analytical protocols was found. Voltammetry provides a tool for the prescreening of synthetic cannabinoid derivatives in seized materials and biological samples.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26905258     DOI: 10.1021/acs.analchem.6b00368

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

2.  Highly sensitive screening and analytical characterization of synthetic cannabinoids in nine different herbal mixtures.

Authors:  Vera L Alves; João L Gonçalves; Joselin Aguiar; Maria J Caldeira; Helena M Teixeira; José S Câmara
Journal:  Anal Bioanal Chem       Date:  2021-02-11       Impact factor: 4.142

3.  Cross-Reactive Plasmonic Aptasensors for Controlled Substance Identification.

Authors:  Joshua N Yoho; Brian Geier; Claude C Grigsby; Joshua A Hagen; Jorge L Chávez; Nancy Kelley-Loughnane
Journal:  Sensors (Basel)       Date:  2017-08-23       Impact factor: 3.576

4.  Rapid Determination of the 'Legal Highs' 4-MMC and 4-MEC by Spectroelectrochemistry: Simultaneous Cyclic Voltammetry and In Situ Surface-Enhanced Raman Spectroscopy.

Authors:  Jerson González-Hernández; Colby Edward Ott; María Julia Arcos-Martínez; Álvaro Colina; Aránzazu Heras; Ana Lorena Alvarado-Gámez; Roberto Urcuyo; Luis E Arroyo-Mora
Journal:  Sensors (Basel)       Date:  2021-12-31       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.