Literature DB >> 26904919

Stress shielding in bone of a bone-cement interface.

Qing-Hang Zhang1, Andrew Cossey2, Jie Tong3.   

Abstract

Cementation is one of the main fixation methods used in joint replacement surgeries such as Total Knee Replacement (TKR). This work was prompted by a recent retrieval study, which shows losses up to 75% of the bone stock at the bone-cement interface ten years post TKR. It aims to examine the effects of cementation on the stress shielding of the interfacing bone, when the influence of an implant is removed. A micromechanics finite element study of a generic bone-cement interface is presented here, where bone elements in the partially and the fully interdigitated regions were evaluated under selected load cases. The results revealed significant stress shielding effect in the bone of all bone-cement interface regions, particularly in fully interdigitated region. This finding may be useful in the studies of implant fixation and other related orthopedic treatment strategies.
Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

Keywords:  Bone resorption; Bone-cement interface; Finite element analysis; Stress shielding

Mesh:

Substances:

Year:  2016        PMID: 26904919     DOI: 10.1016/j.medengphy.2016.01.009

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Similitude of cement-bone micromechanics in cemented rat and human knee replacement.

Authors:  Kenneth A Mann; Mark A Miller; Megan E Tatusko; Megan E Oest
Journal:  J Orthop Res       Date:  2020-03-20       Impact factor: 3.494

2.  Strain shielding in trabecular bone at the tibial cement-bone interface.

Authors:  Priyanka Srinivasan; Mark A Miller; Nico Verdonschot; Kenneth A Mann; Dennis Janssen
Journal:  J Mech Behav Biomed Mater       Date:  2016-11-10

3.  A modelling approach demonstrating micromechanical changes in the tibial cemented interface due to in vivo service.

Authors:  Priyanka Srinivasan; Mark A Miller; Nico Verdonschot; Kenneth A Mann; Dennis Janssen
Journal:  J Biomech       Date:  2017-02-27       Impact factor: 2.712

4.  Peri-Implant Distribution of Polyethylene Debris in Postmortem-Retrieved Knee Arthroplasties: Can Polyethylene Debris Explain Loss of Cement-Bone Interlock in Successful Total Knee Arthroplasties?

Authors:  Karen I Cyndari; Jacklyn R Goodheart; Mark A Miller; Megan E Oest; Timothy A Damron; Kenneth A Mann
Journal:  J Arthroplasty       Date:  2017-02-03       Impact factor: 4.757

5.  Trabecular resorption patterns of cement-bone interlock regions in total knee replacements.

Authors:  Jacklyn R Goodheart; Mark A Miller; Megan E Oest; Kenneth A Mann
Journal:  J Orthop Res       Date:  2017-05-15       Impact factor: 3.494

Review 6.  Bone cement as a local chemotherapeutic drug delivery carrier in orthopedic oncology: A review.

Authors:  Sunjeev S Phull; Alireza Rahimnejad Yazdi; Michelle Ghert; Mark R Towler
Journal:  J Bone Oncol       Date:  2020-12-16       Impact factor: 4.072

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.