Literature DB >> 26901460

Multi-input and -output logic circuits based on bioelectrocatalysis with horseradish peroxidase and glucose oxidase immobilized in multi-responsive copolymer films on electrodes.

Xue Yu1, Wenjing Lian1, Jiannan Zhang2, Hongyun Liu3.   

Abstract

Herein, poly(N-isopropylacrylamide-co-N,N'-dimethylaminoethylmethacrylate) copolymer films were polymerized on electrode surface with a simple one-step method, and the enzyme horseradish peroxidase (HRP) was embedded in the films simultaneously, which were designated as P(NiPAAm-co-DMEM)-HRP. The films exhibited a reversible structure change with the external stimuli, such as pH, CO2, temperature and SO4(2-), causing the cyclic voltammetric (CV) response of electroactive K3Fe(CN)6 at the film electrodes to display the corresponding multi-stimuli sensitive ON-OFF behavior. Based on the switchable CV property of the system and the electrochemical reduction of H2O2 catalyzed by HRP in the films and mediated by Fe(CN)6(3-) in solution, a 5-input/3-output logic gate was established. To further increase the complexity of the logic system, another enzyme glucose oxidase (GOD) was added into the films, designated as P(NiPAAm-co-DMEM)-HRP-GOD. In the presence of oxygen, the oxidation of glucose in the solution was catalyzed by GOD in the films, and the produced H2O2 in situ was recognized and electrocatalytically reduced by HRP and mediated by Fe(CN)6(3-). Based on the bienzyme films, a cascaded or concatenated 4-input/3-output logic gate system was proposed. The present work combined the multi-responsive interface with bioelectrocatalysis to construct cascaded logic circuits, which might open a new avenue to develop biocomputing elements with more sophisticated functions and design novel glucose biosensors.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioelectrocatalysis; Glucose oxidase; Horseradish peroxidase; Logic gate; Multi-responsive interface

Mesh:

Substances:

Year:  2016        PMID: 26901460     DOI: 10.1016/j.bios.2016.02.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

Review 1.  Conformational dynamics and enzyme evolution.

Authors:  Dušan Petrović; Valeria A Risso; Shina Caroline Lynn Kamerlin; Jose M Sanchez-Ruiz
Journal:  J R Soc Interface       Date:  2018-07       Impact factor: 4.118

2.  Construction of Multiple Switchable Sensors and Logic Gates Based on Carboxylated Multi-Walled Carbon Nanotubes/Poly(N,N-Diethylacrylamide).

Authors:  Xuemei Wu; Xiaoqing Bai; Yang Ma; Jie Wei; Juan Peng; Keren Shi; Huiqin Yao
Journal:  Sensors (Basel)       Date:  2018-10-08       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.