Literature DB >> 26901026

Reassessment and Follow-Up Results of BI-RADS Category 3 Lesions Detected on Screening Breast Ultrasound.

Eun Young Chae1, Joo Hee Cha1, Hee Jung Shin1, Woo Jung Choi1, Hak Hee Kim1.   

Abstract

OBJECTIVE: The purpose of this study is to determine the frequency and the malignancy rate of BI-RADS category 3 lesions detected on screening breast ultrasound and to reassess whether they satisfied the requirements of the American College of Radiology Imaging Network (ACRIN) 6666 protocol.
MATERIALS AND METHODS: Of 28,796 asymptomatic women who underwent screening mammography during 2 years, 12,187 underwent additional ultrasound as part of the screening. Patients for whom BI-RADS category 3 lesions were seen on the ultrasound were selected. We reviewed the initial ultrasound showing BI-RADS category 3 lesions and mammograms. We also investigated the clinical outcome of these lesions using the reference standard of a combination of pathologic analysis and follow-up for at least 24 months.
RESULTS: The frequency of BI-RADS category 3 lesions detected on screening ultrasound was 14.6% (1783/12,187). Of the 1164 patients with a follow-up duration of at least 24 months or whose lesions were biopsied, eight were eventually proven to have malignancy (0.7%). The malignancy rate was 2.2% (4/184) for patients with abnormal mammograms and 0.4% (4/980) for those with normal mammograms. When the ACRIN 6666 protocols were strictly applied, 225 (19.3%) lesions were retrospectively recategorized as BI-RADS category 4 (n = 12) or category 2 (n = 213). All detected malignancies were early breast cancers with no lymph node metastasis.
CONCLUSION: Although the frequency of ultrasound BI-RADS category 3 lesions is considerably high (14.6%), the malignancy rate is very low (0.7%), especially in patients with a normal mammogram. Therefore, with BI-RADS category 3 assessment, careful evaluation is required to avoid unnecessary short-interval follow-up or biopsy.

Entities:  

Keywords:  BI-RADS; breast neoplasm; probably benign lesion; ultrasound

Mesh:

Year:  2016        PMID: 26901026     DOI: 10.2214/AJR.15.14785

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

1.  Management for BI-RADS category 3 lesions detected in preoperative breast MR imaging of breast cancer patients.

Authors:  Hye Mi Gweon; Nariya Cho; Soo-Yeon Kim; Hye Ryoung Koo; Mirinae Seo; Ajung Chu; Eun Ju Son
Journal:  Eur Radiol       Date:  2017-01-12       Impact factor: 5.315

2.  Growing BI-RADS category 3 lesions on follow-up breast ultrasound: malignancy rates and worrisome features.

Authors:  Su Min Ha; Eun Young Chae; Joo Hee Cha; Hee Jung Shin; Woo Jung Choi; Hak Hee Kim
Journal:  Br J Radiol       Date:  2018-04-25       Impact factor: 3.039

3.  Reducing Unnecessary Biopsy and Follow-up of Benign Cystic Breast Lesions.

Authors:  Wendie A Berg
Journal:  Radiology       Date:  2020-02-18       Impact factor: 11.105

Review 4.  BI-RADS 3 on Screening Breast Ultrasound: What Is It and What Is the Appropriate Management?

Authors:  Wendie A Berg
Journal:  J Breast Imaging       Date:  2021-08-15

5.  Medical auditing of whole-breast screening ultrasonography.

Authors:  Min Jung Kim
Journal:  Ultrasonography       Date:  2017-02-16

6.  Analysis of utilization patterns and associated costs of the breast imaging and diagnostic procedures after screening mammography.

Authors:  Anna Vlahiotis; Brian Griffin; A Thomas Stavros; Jay Margolis
Journal:  Clinicoecon Outcomes Res       Date:  2018-03-26

7.  Follow-up Outcomes of Benign Pathology Initially Assigned as Breast Imaging Reporting and Data System Category 4A and 3.

Authors:  Ji Young You; Hee Jung Suh; Yunju Kim; Jae Kwan Jun; Haydee Ojeda-Fournier; Kyounglan Ko
Journal:  J Breast Cancer       Date:  2017-09-22       Impact factor: 3.588

8.  Follow-Up Intervals for Breast Imaging Reporting and Data System Category 3 Lesions on Screening Ultrasound in Screening and Tertiary Referral Centers.

Authors:  Sun Huh; Hee Jung Suh; Eun Kyung Kim; Min Jung Kim; Jung Hyun Yoon; Vivian Youngjean Park; Hee Jung Moon
Journal:  Korean J Radiol       Date:  2020-09       Impact factor: 3.500

9.  Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria.

Authors:  Sefiya A Olarinoye-Akorede; Garba H Yunusa; Halima Aliyu; Ahmed U Hamidu
Journal:  SA J Radiol       Date:  2018-11-01

10.  Breast lesions excised via vacuum-assisted system: could we get any clues for B3 lesions before excision biopsy?

Authors:  Liang Zheng; Fufu Zheng; Zhaomin Xing; Yunjian Zhang; Yongxin Li; Hongbiao Xu; Yuanhui Lai; Jie Li; Wenjian Wang
Journal:  BMC Cancer       Date:  2021-05-29       Impact factor: 4.430