Literature DB >> 26900192

Variation in Laboratory Reporting of Haemolysis - a Need for Harmonisation.

Penny Petinos1, Stephanie Gay1, Tony Badrick1.   

Abstract

AIM: The purpose of this survey was to determine the cut-offs being used by Australian laboratories using their instrument's Haemolysis Index (HI), whether these cut-offs vary, and at what level of haemolysis (or haemolysis index) did laboratories stop reporting one or more analytes. This was done in response to the large numbers of haemolysed samples reported in the RCPAQAP Key Incident Monitoring and Management System External Quality Assurance program (KIMMS EQA) and lack of information in the literature at the time regarding what to do once a haemolysed sample was identified. As it was known from discussions with laboratory personnel that different instruments reported their HI differently, we asked for the results to be provided in g/L free haemoglobin.
METHOD: An electronic survey was conducted with participants enrolled in the RCPA Quality Assurance Programs with a total of 68 laboratories responding to this survey. Some questions attracted a lower level of response.
RESULTS: The responses showed a poor understanding of the relationship between HI units and haemoglobin concentration. There was wide variation in the way HI results were reported and thus comparing cut-off values for reporting specific analytes based on the HI was impossible to determine.
CONCLUSION: There is a need to harmonise the way laboratories report analytes in the presence of haemolysis. This would involve adopting a uniform definition of HI and a protocol for laboratories to confirm for themselves the level of HI at which each analyte is no longer reported, as this is method dependent and so will vary from laboratory to laboratory.

Entities:  

Year:  2015        PMID: 26900192      PMCID: PMC4743621     

Source DB:  PubMed          Journal:  Clin Biochem Rev        ISSN: 0159-8090


  6 in total

1.  Errors in a stat laboratory: types and frequencies 10 years later.

Authors:  Paolo Carraro; Mario Plebani
Journal:  Clin Chem       Date:  2007-05-24       Impact factor: 8.327

2.  Multicenter evaluation of the hemolysis index in automated clinical chemistry systems.

Authors:  Giuseppe Lippi; Gian Luca Salvagno; Norbert Blanckaert; Davide Giavarina; Sol Green; Steve Kitchen; Vladimir Palicka; Anne J Vassault; Mario Plebani
Journal:  Clin Chem Lab Med       Date:  2009       Impact factor: 3.694

3.  Harmonization in hemolysis detection and prevention. A working group of the Catalonian Health Institute (ICS) experience.

Authors:  Pilar Fernandez; María Antonia Llopis; Carmen Perich; Maria Jesús Alsina; Virtudes Alvarez; Carmen Biosca; Gloria Busquets; Maria Vicenta Domenech; Rubén Gómez; Isabel Llovet; Joana Minchinela; Rosa Pastor; Rosa Ruiz; Ester Tarrés; Mercè Ibarz; Margarita Simón; Mercè Montesinos
Journal:  Clin Chem Lab Med       Date:  2014-11       Impact factor: 3.694

4.  Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients.

Authors:  Giuseppe Lippi; Davide Giavarina; Matteo Gelati; Gian Luca Salvagno
Journal:  Clin Chim Acta       Date:  2013-12-18       Impact factor: 3.786

5.  Harmonization of automated hemolysis index assessment and use: Is it possible?

Authors:  Alberto Dolci; Mauro Panteghini
Journal:  Clin Chim Acta       Date:  2013-10-24       Impact factor: 3.786

6.  Haemolysis as Influence & Interference Factor.

Authors:  L Thomas
Journal:  EJIFCC       Date:  2002-06-10
  6 in total
  3 in total

1.  Physiological interventions in cardiac arrest: passing the pilot phase.

Authors:  Niklas Nielsen; Alain Cariou; Christian Hassager
Journal:  Intensive Care Med       Date:  2018-12-10       Impact factor: 17.440

2.  Consensus Statement for the Management and Reporting of Haemolysed Specimens.

Authors:  Tony Badrick; Harry Barden; Shaw Callen; Goce Dimeski; Stephanie Gay; Peter Graham; Penny Petinos; Ken Sikaris
Journal:  Clin Biochem Rev       Date:  2016-12

3.  Correction to: Physiological interventions in cardiac arrest: passing the pilot phase.

Authors:  Niklas Nielsen; Alain Cariou; Christian Hassager
Journal:  Intensive Care Med       Date:  2019-02       Impact factor: 17.440

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.