Abstract

Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  High-performance liquid chromatography; Pesticides; Pharmaceutical drugs; Phenolics; Polymeric ionic liquids; Solid-phase microextraction

Mesh:

Substances:

Year:  2016        PMID: 26896916     DOI: 10.1016/j.chroma.2016.02.027

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  The Influence of Ionic Liquids on the Effectiveness of Analytical Methods Used in the Monitoring of Human and Veterinary Pharmaceuticals in Biological and Environmental Samples-Trends and Perspectives.

Authors:  Natalia Treder; Tomasz Bączek; Katarzyna Wychodnik; Justyna Rogowska; Lidia Wolska; Alina Plenis
Journal:  Molecules       Date:  2020-01-10       Impact factor: 4.411

2.  Oriented ZnO nanoflakes on nickel-titanium alloy fibers for solid-phase microextraction of polychlorinated biphenyls and polycyclic aromatic hydrocarbons.

Authors:  Jiajian Du; Huiju Wang; Rong Zhang; Xuemei Wang; Xinzhen Du; Xiaoquan Lu
Journal:  Mikrochim Acta       Date:  2018-09-01       Impact factor: 5.833

3.  Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples.

Authors:  Maria Espina-Benitez; Lilia Araujo; Avismelsi Prieto; Alberto Navalón; José Luis Vílchez; Paola Valera; Ana Zambrano; Vincent Dugas
Journal:  Int J Environ Res Public Health       Date:  2017-07-07       Impact factor: 3.390

4.  Determination of Volatile Water Pollutants Using Cross-Linked Polymeric Ionic Liquid as Solid Phase Micro-Extraction Coatings.

Authors:  Yuan Tian; Xilan Feng; Yuping Zhang; Quan Yu; Xiaohao Wang; Mengkui Tian
Journal:  Polymers (Basel)       Date:  2020-02-02       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.