Literature DB >> 26896752

Novel measurement method on plain radiographs to predict postoperative stem anteversion in cementless THA.

Markus Weber1, Benedikt Messmer1, Michael Woerner1, Joachim Grifka1, Tobias Renkawitz1.   

Abstract

Preoperative knowledge of femoral stem anteversion can reduce instability and impingement especially using the standard "cup first" technique in cementless total hip arthroplasty (THA). In this study, we asked whether stems at risk of retroversion or high anteversion (>20°) can be detected preoperatively using hip radiographs in two planes (anteroposterior and Lauenstein). In 123 patients undergoing cementless THA using a non-anatomic, non-modular, straight stem, low centered hip radiographs in two planes were obtained preoperatively and three-dimensional computed tomography (3D-CT) 6 week postoperatively. The novel developed Isthmus Ratio (iRatio) as the relation between canal isthmus and calcar isthmus in the anteroposterior and Lauenstein view was calculated by two observers twice in a 6-week interval. iRatio was compared to postoperative 3D-CT stem version measured by an independent and blinded, external institute. We found a correlation between mean radiographic iRatio and 3D-CT stem torsion of r = 0.578 (p < 0.0001). The observers had excellent agreements within (ICC ≥0.918) and between (mean CCC = 0.967) radiographic iRatio measurements. Eighty-one percent (21/26) of the retroverted cementless stems had a preoperative iRatio below 0.35 and 91% (10/11) of stems with an anteversion exceeding 20° an iRatio above 0.55, respectively. The novel iRatio represents a feasible and reliable method for analyzing anteversion of the final stem on plain radiographs before cementless THA with a straight, tapered stem. iRatios below 0.35 and above 0.55 represent a warning of retroversion and anteversion more than 20° of the final stem, respectively.
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2025-2030, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  femoral anatomy; radiography; stem version; total hip arthroplasty

Mesh:

Year:  2016        PMID: 26896752     DOI: 10.1002/jor.23202

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  2 in total

1.  Which Safe Zone Is Safe in Total Hip Arthroplasty? The Effect of Bony Impingement.

Authors:  Markus Weber; Frederik von Kunow; Moritz Innmann; Matthias Meyer; Max Thieme; Seth Jerabek; Tobias Renkawitz
Journal:  J Pers Med       Date:  2022-05-18

2.  Inaccurate offset restoration in total hip arthroplasty results in reduced range of motion.

Authors:  Markus Weber; Christian Merle; Danyal H Nawabi; Sebastian Dendorfer; Joachim Grifka; Tobias Renkawitz
Journal:  Sci Rep       Date:  2020-08-06       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.