Literature DB >> 26892919

Diffusion-weighted quantitative MRI to diagnose benign conditions from malignancies of the anterior mediastinum: Improvement of diagnostic accuracy by comparing perfusion-free to perfusion-sensitive measurements of the apparent diffusion coefficient.

Adriano Massimiliano Priola1, Sandro Massimo Priola1, Dario Gned1, Edoardo Piacibello1, Diego Sardo1, Guido Parvis2, Davide Torti2, Francesco Ardissone3, Andrea Veltri1.   

Abstract

PURPOSE: To compare perfusion-free to perfusion-sensitive measurements of the apparent diffusion coefficient (ADC) to diagnose benign conditions from malignancies of the anterior mediastinum.
MATERIALS AND METHODS: Seventy-six subjects were divided into a "benign conditions" group (A, n = 44) and a "malignancies" group (B, n = 32), based on histological findings. diffusion-weighted magnetic resonance imaging (DW-MRI) was performed at b of 0/150/800 sec/mm(2) . The ADCs were obtained on an ADC map by including (perfusion-sensitive = ADCb0-800 ) and excluding (perfusion-free = ADCb150-800 ) the b = 0 sec/mm(2) . The Mann-Whitney U-test was used to detect differences in ADCb0-800 compared with ADCb150-800 values between all cases, benign conditions, and malignancies. The same test was used to evaluate differences in ADCs between the two groups for each type of measurement (ADCb0-800 and ADCb150-800 ), and receiver-operating characteristic (ROC) curves were obtained to evaluate discrimination abilities with comparison of areas-under-ROC-curves (AUROC). Optimal cutpoints for discrimination between groups were determined by the Youden-Index with computation of accuracy.
RESULTS: The median ADCb0-800 was significantly greater compared with ADCb150-800 for all cases (P = 0.0014), benign conditions (P = 0.0412), and malignancies (P = 0.0001). The median percentage of increase was 5.30% for group-A and 22.39% for group-B (P < 0.0001). AUROC of ADC in discriminating between groups was significantly greater for ADCb150-800 (0.932) compared with ADCb0-800 (0.831) (P = 0.001). The optimal cutpoint for distinction between groups was 1.52 × 10(-3) mm(2) /sec (sensitivity = 93.7%, specificity = 88.6%, accuracy = 90.8%) for ADCb150-800 and 1.75 × 10(-3) mm(2) /sec (sensitivity = 75.0%, specificity = 79.5%, accuracy = 77.6%) for ADCb0-800 .
CONCLUSION: The use of perfusion-free ADC measurements significantly improves diagnostic accuracy of DW-MRI in differentiating benign conditions from malignancies of the anterior mediastinum. J. Magn. Reson. Imaging 2016;44:758-769.
© 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  anterior mediastinum; apparent diffusion coefficient; b value; diffusion-weighted magnetic resonance imaging; perfusion

Mesh:

Year:  2016        PMID: 26892919     DOI: 10.1002/jmri.25203

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Nonsuppressing normal thymus on chemical-shift MR imaging and anterior mediastinal lymphoma: differentiation with diffusion-weighted MR imaging by using the apparent diffusion coefficient.

Authors:  Adriano Massimiliano Priola; Sandro Massimo Priola; Dario Gned; Maria Teresa Giraudo; Andrea Veltri
Journal:  Eur Radiol       Date:  2017-11-15       Impact factor: 5.315

2.  Predicting pathological subtypes and stages of thymic epithelial tumors using DWI: value of combining ADC and texture parameters.

Authors:  Bo Li; Yong-Kang Xin; Gang Xiao; Gang-Feng Li; Shi-Jun Duan; Yu Han; Xiu-Long Feng; Wei-Qiang Yan; Wei-Cheng Rong; Shu-Mei Wang; Yu-Chuan Hu; Guang-Bin Cui
Journal:  Eur Radiol       Date:  2019-03-15       Impact factor: 5.315

3.  Apparent diffusion coefficient values detected by diffusion-weighted imaging in the prognosis of patients with locally advanced esophageal squamous cell carcinoma receiving chemoradiation.

Authors:  Shu Liu; Fuxi Zhen; Nana Sun; Jiayan Chen; Yuandong Cao; Sheng Zhang; Hongyan Cheng; Xiaolin Ge; Xinchen Sun
Journal:  Onco Targets Ther       Date:  2016-09-21       Impact factor: 4.147

4.  Diffusion-Weighted MRI Reflects Proliferative Activity in Primary CNS Lymphoma.

Authors:  Stefan Schob; Jonas Meyer; Matthias Gawlitza; Clara Frydrychowicz; Wolf Müller; Matthias Preuss; Lionel Bure; Ulf Quäschling; Karl-Titus Hoffmann; Alexey Surov
Journal:  PLoS One       Date:  2016-08-29       Impact factor: 3.240

5.  Incremental Value of Magnetic Resonance Imaging in Further Characterizing Hypodense Mediastinal and Paracardiac Lesions Identified on Computed Tomography.

Authors:  Abhishek Chaturvedi; Chris Gange; Hakan Sahin; Apeksha Chaturvedi
Journal:  J Clin Imaging Sci       Date:  2018-03-12

6.  Extracellular volume fraction measurement correlates with lymphocyte abundance in thymic epithelial tumors.

Authors:  Chao-Chun Chang; Chia-Ying Lin; Chang-Yao Chu; Yi-Cheng Hsiung; Ming-Tsung Chuang; Yau-Lin Tseng; Yi-Ting Yen
Journal:  Cancer Imaging       Date:  2020-10-07       Impact factor: 3.909

7.  Importance of measurement repeatability of semi-quantitative imaging through PET-CT and PET-MR imaging in oncology.

Authors:  Adriano Massimiliano Priola; Sandro Massimo Priola
Journal:  Transl Cancer Res       Date:  2019-11       Impact factor: 1.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.