Literature DB >> 26891785

Stability of Routine Biochemical Analytes in Whole Blood and Plasma From Lithium Heparin Gel Tubes During 6-hr Storage.

Denis Monneret1, Alexandre Godmer2, Ronan Le Guen2, Clotilde Bravetti2, Cecile Emeraud2, Anthony Marteau2, Rana Alkouri2, Fouzi Mestari2, Sylvie Dever2, Françoise Imbert-Bismut2, Dominique Bonnefont-Rousselot2,3,4.   

Abstract

BACKGROUND: The stability of biochemical analytes has already been investigated, but results strongly differ depending on parameters, methodologies, and sample storage times. We investigated the stability for many biochemical parameters after different storage times of both whole blood and plasma, in order to define acceptable pre- and postcentrifugation delays in hospital laboratories.
METHODS: Twenty-four analytes were measured (Modular® Roche analyzer) in plasma obtained from blood collected into lithium heparin gel tubes, after 2-6 hr of storage at room temperature either before (n = 28: stability in whole blood) or after (n = 21: stability in plasma) centrifugation. Variations in concentrations were expressed as mean bias from baseline, using the analytical change limit (ACL%) or the reference change value (RCV%) as acceptance limit.
RESULTS: In tubes stored before centrifugation, mean plasma concentrations significantly decreased after 3 hr for phosphorus (-6.1% [95% CI: -7.4 to -4.7%]; ACL 4.62%) and lactate dehydrogenase (LDH; -5.7% [95% CI: -7.4 to -4.1%]; ACL 5.17%), and slightly decreased after 6 hr for potassium (-2.9% [95% CI: -5.3 to -0.5%]; ACL 4.13%). In plasma stored after centrifugation, mean concentrations decreased after 6 hr for bicarbonates (-19.7% [95% CI: -22.9 to -16.5%]; ACL 15.4%), and moderately increased after 4 hr for LDH (+6.0% [95% CI: +4.3 to +7.6%]; ACL 5.17%). Based on RCV, all the analytes can be considered stable up to 6 hr, whether before or after centrifugation.
CONCLUSION: This study proposes acceptable delays for most biochemical tests on lithium heparin gel tubes arriving at the laboratory or needing to be reanalyzed.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  biochemical analytes; plasma; preanalytical; stability; storage time; whole blood

Mesh:

Substances:

Year:  2016        PMID: 26891785      PMCID: PMC6807083          DOI: 10.1002/jcla.21909

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  22 in total

1.  Stability studies of twenty-four analytes in human plasma and serum.

Authors:  Bobby L Boyanton; Kenneth E Blick
Journal:  Clin Chem       Date:  2002-12       Impact factor: 8.327

2.  The reference change value: a proposal to interpret laboratory reports in serial testing based on biological variation.

Authors:  C Ricós; F Cava; J V García-Lario; A Hernández; N Iglesias; C V Jiménez; J Minchinela; C Perich; M Simón; M V Domenech; V Alvarez
Journal:  Scand J Clin Lab Invest       Date:  2004       Impact factor: 1.713

3.  Stability study of 81 analytes in human whole blood, in serum and in plasma.

Authors:  Christiane Oddoze; Elise Lombard; Henri Portugal
Journal:  Clin Biochem       Date:  2012-01-18       Impact factor: 3.281

4.  Comparison of measured and calculated bicarbonate values.

Authors:  Vivek Kumar; Brad S Karon
Journal:  Clin Chem       Date:  2008-09       Impact factor: 8.327

5.  Changes in serum chemical values as a result of prolonged contact with the clot.

Authors:  R H Laessig; A A Indriksons; D J Hassemer; T A Paskey; T H Schwartz
Journal:  Am J Clin Pathol       Date:  1976-09       Impact factor: 2.493

6.  Centrifugation protocols: tests to determine optimal lithium heparin and citrate plasma sample quality.

Authors:  Goce Dimeski; Connie Solano; Mark K Petroff; Matthew Hynd
Journal:  Ann Clin Biochem       Date:  2011-03-11       Impact factor: 2.057

7.  Optimal conditions and comparison of lactate dehydrogenase catalysis of the lactate-to-pyruvate and pyruvate-to-lactate reactions in human serum at 25, 30, and 37 degrees C.

Authors:  S N Buhl; K Y Jackson
Journal:  Clin Chem       Date:  1978-05       Impact factor: 8.327

8.  Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

Authors:  Nicole Böckel-Frohnhöfer; Ulrich Hübner; Björn Hummel; Jürgen Geisel
Journal:  Scand J Clin Lab Invest       Date:  2014-06-09       Impact factor: 1.713

9.  [Preanalytical phase and accreditation: acceptance criteria for samples of multisite laboratory].

Authors:  Pascale Dialma; Stéphane Piaulenne; Sonia Baty; Thierry Zeitoun
Journal:  Ann Biol Clin (Paris)       Date:  2013 Jan-Feb       Impact factor: 0.459

10.  Stability of 35 biochemical and immunological routine tests after 10 hours storage and transport of human whole blood at 21°C.

Authors:  Linda O Henriksen; Nina R Faber; Mette F Moller; Ebba Nexo; Annebirthe B Hansen
Journal:  Scand J Clin Lab Invest       Date:  2014-07-02       Impact factor: 1.713

View more
  4 in total

1.  Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube.

Authors:  Sunghwan Shin; Jongwon Oh; Hyung-Doo Park
Journal:  Ann Lab Med       Date:  2020-08-25       Impact factor: 3.464

2.  Sample Management: Stability of Plasma and Serum on Different Storage Conditions.

Authors:  Carlos Fernando Yauli Flores; Ángela de Las Mercedes Hurtado Pineda; Victoria Maritza Cevallos Bonilla; Klever Sáenz-Flor
Journal:  EJIFCC       Date:  2020-03-20

3.  Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels.

Authors:  Olivier Bausset; Olivier Juvet; Caroline Staller-Gobelli; Emilie Milano; Jean-Paul Bausset
Journal:  Pract Lab Med       Date:  2017-02-03

4.  The impact of pre-analytical variations on biochemical analytes stability: A systematic review.

Authors:  Mehdi Hedayati; S Adeleh Razavi; Seti Boroomand; Sima Kheradmand Kia
Journal:  J Clin Lab Anal       Date:  2020-09-01       Impact factor: 3.124

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.