Literature DB >> 26890778

Evaluation of Cerebrospinal Fluid Assay Variability in Alzheimer's Disease.

Matthew T White1,2, Leslie M Shaw3, Sharon X Xie4.   

Abstract

Studies of cerebrospinal fluid (CSF) biomarkers in Alzheimer's disease (AD) have indicated that much of the variability observed in the biomarkers may be due to measurement error. Biomarkers are often obtained with measurement error, which may make the diagnostic biomarker appear less effective than it truly is. In the Alzheimer's Disease Neuroimaging Initiative (ADNI) database, technical replicates of CSF biomarkers are available; the National Alzheimer's Coordinating Center database contains longitudinal replicates of CSF biomarkers. We focus on the area under the receiver operating characteristic curve (AUC) as the measure of diagnostic effectiveness for differentiating AD from normal cognition using CSF biomarkers and compare AUC estimates obtained by a more standard, naïve method (which uses a single observation per subject and ignores measurement error) to a maximum likelihood (ML) based method (which uses all replicates per subject and adjusts for measurement error). The choice of analysis method depends upon the noise to signal ratio (i.e., the magnitude of the measurement error variability relative to the true biomarker variability); moderate to high ratios may significantly bias the naïve AUC estimate, and the ML-based method would be preferred. The noise to signal ratios were low for the ADNI biomarkers but high for the tTau and pTau biomarkers in NACC. Correspondingly, the naïve and ML-based AUC estimates were nearly identical in the ADNI data but dissimilar for the tTau and pTau biomarkers in the NACC data. Therefore, using the naïve method is adequate for analysis of CSF biomarkers in the ADNI study, but the ML method is recommended for the NACC data.

Entities:  

Keywords:  Alzheimer’s disease; biomarkers; diagnostic testing; maximum likelihood; measurement error; replicate data

Mesh:

Substances:

Year:  2016        PMID: 26890778      PMCID: PMC4930357          DOI: 10.3233/JAD-151045

Source DB:  PubMed          Journal:  J Alzheimers Dis        ISSN: 1387-2877            Impact factor:   4.472


  16 in total

1.  The effect of random measurement error on receiver operating characteristic (ROC) curves.

Authors:  D Faraggi
Journal:  Stat Med       Date:  2000-01-15       Impact factor: 2.373

2.  Measuring the effectiveness of diagnostic markers in the presence of measurement error through the use of ROC curves.

Authors:  B Reiser
Journal:  Stat Med       Date:  2000-08-30       Impact factor: 2.373

3.  Statistical inference for the area under the receiver operating characteristic curve in the presence of random measurement error.

Authors:  E F Schisterman; D Faraggi; B Reiser; M Trevisan
Journal:  Am J Epidemiol       Date:  2001-07-15       Impact factor: 4.897

4.  Interval estimation for the area under the receiver operating characteristic curve when data are subject to error.

Authors:  Yanhong Li; John J Koval; Allan Donner; G Y Zou
Journal:  Stat Med       Date:  2010-10-30       Impact factor: 2.373

5.  Measurement error and confidence intervals for ROC curves.

Authors:  Tor D Tosteson; John P Buonaccorsi; Eugene Demidenko; Wendy A Wells
Journal:  Biom J       Date:  2005-08       Impact factor: 2.207

6.  A worldwide multicentre comparison of assays for cerebrospinal fluid biomarkers in Alzheimer's disease.

Authors:  N A Verwey; W M van der Flier; K Blennow; C Clark; S Sokolow; P P De Deyn; D Galasko; H Hampel; T Hartmann; E Kapaki; L Lannfelt; P D Mehta; L Parnetti; A Petzold; T Pirttila; L Saleh; A Skinningsrud; J C V Swieten; M M Verbeek; J Wiltfang; S Younkin; P Scheltens; M A Blankenstein
Journal:  Ann Clin Biochem       Date:  2009-04-02       Impact factor: 2.057

7.  Use of cerebrospinal fluid biomarkers for diagnosis of incipient Alzheimer disease in patients with mild cognitive impairment.

Authors:  Robert A Dean; Leslie M Shaw
Journal:  Clin Chem       Date:  2009-11-19       Impact factor: 8.327

8.  Qualification of the analytical and clinical performance of CSF biomarker analyses in ADNI.

Authors:  Leslie M Shaw; Hugo Vanderstichele; Malgorzata Knapik-Czajka; Michal Figurski; Els Coart; Kaj Blennow; Holly Soares; Adam J Simon; Piotr Lewczuk; Robert A Dean; Eric Siemers; William Potter; Virginia M-Y Lee; John Q Trojanowski
Journal:  Acta Neuropathol       Date:  2011-02-11       Impact factor: 17.088

9.  Receiver operating characteristic studies and measurement errors.

Authors:  M Coffin; S Sukhatme
Journal:  Biometrics       Date:  1997-09       Impact factor: 2.571

10.  Cerebrospinal fluid biomarker signature in Alzheimer's disease neuroimaging initiative subjects.

Authors:  Leslie M Shaw; Hugo Vanderstichele; Malgorzata Knapik-Czajka; Christopher M Clark; Paul S Aisen; Ronald C Petersen; Kaj Blennow; Holly Soares; Adam Simon; Piotr Lewczuk; Robert Dean; Eric Siemers; William Potter; Virginia M-Y Lee; John Q Trojanowski
Journal:  Ann Neurol       Date:  2009-04       Impact factor: 10.422

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.