Literature DB >> 26890091

Development and optimization of a sensitive TaqMan® real-time PCR with synthetic homologous extrinsic control for quantitation of Human cytomegalovirus viral load.

Svetoslav Nanev Slavov1,2, Katia Kaori Otaguiri1,3, Glauciane Garcia de Figueiredo4, Aparecida Yulie Yamamoto4, Marisa Marcia Mussi-Pinhata4, Simone Kashima1,3, Dimas Tadeu Covas1,2.   

Abstract

Human cytomegalovirus (Human herpesvirus 5, HCMV) causes frequent asymptomatic infections in the general population. However, in immunosuppressed patients or congenitally infected infants, HCMV is related to high morbidity and mortality. In such cases, a rapid viral detection is crucial for monitoring the clinical outcome and the antiviral treatment. In this study, we optimized a sensitive biplex TaqMan® real-time PCR for the simultaneous detection and differentiation of a partial HCMV UL97 sequence and homologous extrinsic control (HEC) in the same tube. HEC was represented by a plasmid containing a modified HCMV sequence retaining the original primer binding sites, while the probe sequence was substituted by a phylogenetically divergent one (chloroplast CF0 subunit plant gene). It was estimated that the optimal HEC concentration, which did not influence the HCMV amplification is 1,000 copies/reaction. The optimized TaqMan® PCR demonstrated high analytical sensitivity (6.97 copies/reaction, CI = 95%) and specificity (100%). Moreover, the reaction showed adequate precision (repeatability, CV = 0.03; reproducibility, CV = 0.0027) and robustness (no carry-over or cross-contamination). The diagnostic sensitivity (100%) and specificity (97.8%) were adequate for the clinical application of the molecular platform. The optimized TaqMan® real-time PCR is suitable for HCMV detection and quantitation in predisposed patients and monitoring of the applied antiviral therapy. J. Med. Virol. 88:1604-1612, 2016.
© 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  HCMV; internal controls; molecular detection; optimization

Mesh:

Substances:

Year:  2016        PMID: 26890091     DOI: 10.1002/jmv.24499

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  2 in total

1.  Development of Multiplex Reverse Transcription-Polymerase Chain Reaction for Simultaneous Detection of Influenza A, B and Adenoviruses.

Authors:  Mohsen Nakhaie; Hoorieh Soleimanjahi; Hamid Reza Mollaie; Seyed Mohamad Ali Arabzadeh
Journal:  Iran J Pathol       Date:  2018

Review 2.  Rapid and efficient detection methods of pathogenic swine enteric coronaviruses.

Authors:  Yuguang Fu; Baoyu Li; Guangliang Liu
Journal:  Appl Microbiol Biotechnol       Date:  2020-05-19       Impact factor: 4.813

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.