Literature DB >> 26883549

Intraoperative 3D contrast-enhanced ultrasound (CEUS): a prospective study of 50 patients with brain tumours.

Felix Arlt1, Claire Chalopin2, Andrea Müns3, Jürgen Meixensberger3,2, Dirk Lindner3.   

Abstract

BACKGROUND: Reliable intraoperative resection control during surgery of malignant brain tumours is associated with the longer overall survival of patients. B-mode ultrasound (BUS) is a familiar intraoperative imaging application in neurosurgical procedures and supplies excellent image quality. However, due to resection-induced artefacts, its ability to distinguish between tumour borders, oedema, surrounding tissue and tumour remnants is sometimes limited. In experienced hands, this "bright rim effect" could be reduced. However, it should be determined, if contrast-enhanced ultrasound can improve this situation by providing high-quality imaging during the resection. The aim of this clinical study was to examine contrast-enhanced and three-dimensional reconstructed ultrasound (3D CEUS) in brain tumour surgery regarding the uptake of contrast agent pre- and post-tumour resection, imaging quality and in comparison with postoperative magnetic resonance imaging in different tumour entities.
METHODS: Fifty patients, suffering from various brain tumours intra-axial and extra-axial, who had all undergone surgery with the support of neuronavigation in our neurosurgical department, were included in the study. Their median age was 56 years (range, 28-79). Ultrasound imaging was performed before the Dura was opened and for resection control at the end of tumour resection as defined by the neurosurgeon. A high-end ultrasound (US) device (Toshiba Aplio XG®) with linear and sector probes for B-mode and CEUS was used. Navigation and 3D reconstruction were performed with a LOCALITE SonoNavigator® and the images were transferred digitally (DVI) to the navigation system. The contrast agent consists of echoic micro-bubbles showing tumour vascularisation. The ultrasound images were compared with the corresponding postoperative MR data in order to determine the accuracy and imaging quality of the tumours and tumour remnants after resection.
RESULTS: Different types of tumours were investigated. High, dynamic contrast agent uptake was observed in 19 of 21 patients (90 %) suffering from glioblastoma, while in 2 patients uptake was low and insufficient. In 52.4 % of glioblastoma and grade III astrocytoma patients CEUS led to an improved delineation in comparison to BUS and showed a high-resolution imaging quality of the tumour margins and tumour boarders. Grade II and grade III astrocytoma (n = 6) as well as metastasis (n = 18) also showed high contrast agent uptake, which led in 50 % to an improved imaging quality. In 5 of these 17 patients, intraoperative CEUS for resection control showed tumour remnants, leading to further tumour resection. Patients treated with CEUS showed no increased neurological deficits after tumour resection. No pharmacological side-effects occurred.
CONCLUSIONS: Three-dimensional CEUS is a reliable intraoperative imaging modality and could improve imaging quality. Ninety percent of the high-grade gliomas (HGG, glioblastoma and astrocytoma grade III) showed high contrast uptake with an improved imaging quality in more than 50 %. Gross total resection and incomplete resection of glioblastoma were adequately highlighted by 3D CEUS intraoperatively. The application of US contrast agent could be a helpful imaging tool, especially for resection control in glioblastoma surgery.

Entities:  

Keywords:  Brain tumour surgery; Contrast-enhanced ultrasound; Intraoperative ultrasound; Navigated ultrasound; Resection control

Mesh:

Year:  2016        PMID: 26883549     DOI: 10.1007/s00701-016-2738-z

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  10 in total

Review 1.  Review of the potential of optical technologies for cancer diagnosis in neurosurgery: a step toward intraoperative neurophotonics.

Authors:  Fartash Vasefi; Nicholas MacKinnon; Daniel L Farkas; Babak Kateb
Journal:  Neurophotonics       Date:  2016-12-26       Impact factor: 3.593

2.  Neurophysiological examination combined with functional intraoperative navigation using TMS in patients with brain tumor near the central region-a pilot study.

Authors:  Katharina Köhlert; Katja Jähne; Dorothee Saur; Jürgen Meixensberger
Journal:  Acta Neurochir (Wien)       Date:  2019-07-11       Impact factor: 2.216

Review 3.  Applications of Ultrasound in the Resection of Brain Tumors.

Authors:  Rahul Sastry; Wenya Linda Bi; Steve Pieper; Sarah Frisken; Tina Kapur; William Wells; Alexandra J Golby
Journal:  J Neuroimaging       Date:  2016-08-19       Impact factor: 2.486

Review 4.  Fluorescence Guidance and Intraoperative Adjuvants to Maximize Extent of Resection.

Authors:  Cordelia Orillac; Walter Stummer; Daniel A Orringer
Journal:  Neurosurgery       Date:  2021-10-13       Impact factor: 4.654

Review 5.  New Hope in Brain Glioma Surgery: The Role of Intraoperative Ultrasound. A Review.

Authors:  Maria Angela Pino; Alessia Imperato; Irene Musca; Rosario Maugeri; Giuseppe Roberto Giammalva; Gabriele Costantino; Francesca Graziano; Francesco Meli; Natale Francaviglia; Domenico Gerardo Iacopino; Alessandro Villa
Journal:  Brain Sci       Date:  2018-11-19

6.  High Grade Glioma Treatment in Elderly People: Is It Different Than in Younger Patients? Analysis of Surgical Management Guided by an Intraoperative Multimodal Approach and Its Impact on Clinical Outcome.

Authors:  Giuseppe Maria Vincenzo Barbagallo; Roberto Altieri; Marco Garozzo; Massimiliano Maione; Stefania Di Gregorio; Massimiliano Visocchi; Simone Peschillo; Pasquale Dolce; Francesco Certo
Journal:  Front Oncol       Date:  2021-02-24       Impact factor: 6.244

Review 7.  Application of Multiparametric Intraoperative Ultrasound in Glioma Surgery.

Authors:  Ji Shi; Ye Zhang; Bing Yao; Peixin Sun; Yuanyuan Hao; Haozhe Piao; Xi Zhao
Journal:  Biomed Res Int       Date:  2021-04-16       Impact factor: 3.411

Review 8.  Current Limitations of Intraoperative Ultrasound in Brain Tumor Surgery.

Authors:  Andrej Šteňo; Ján Buvala; Veronika Babková; Adrián Kiss; David Toma; Alexander Lysak
Journal:  Front Oncol       Date:  2021-03-22       Impact factor: 6.244

Review 9.  Intraoperative ultrasound in brain tumor surgery: A review and implementation guide.

Authors:  Luke Dixon; Adrian Lim; Matthew Grech-Sollars; Dipankar Nandi; Sophie Camp
Journal:  Neurosurg Rev       Date:  2022-03-30       Impact factor: 2.800

10.  Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases.

Authors:  Ahmed El Kaffas; Rosa Maria Silveira Sigrist; George Fisher; Sunitha Bachawal; Joy Liau; Huaijun Wang; Alexander Karanany; Isabelle Durot; Jarrett Rosenberg; Dimitre Hristov; Jürgen K Willmann
Journal:  Theranostics       Date:  2017-08-23       Impact factor: 11.556

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.