Use of the G-guide for Measuring Stem Antetorsion During Total Hip Arthroplasty.

Yuki Fujihara, Shigeo Fukunishi, Tomokazu Fukui, Shoji Nishio, Shohei Okahisa, Yu Takeda, Kenji Kurosaka, Shinichi Yoshiya.   

Abstract

Implant positioning is one of the critical factors influencing postoperative outcomes in total hip arthroplasty (THA). Several studies have reported that the postoperative antetorsion (AT) measurement for the femoral stem inserted without navigation showed wide variability. The current authors developed a simple instrument, the Gravity-guide (G-guide), for intraoperative assessment of stem AT and adjustment. They evaluated the effectiveness of the G-guide with postoperative computed tomography (CT) examination. Ninety patients (96 hips) who underwent primary THA using the G-guide for stem adjustment were evaluated. The G-guide consists of 2 parts: one attached to the lower leg and the other attached to the handle of the rasp. The G-guide was used to evaluate the AT at the time of inserting the final rasp. In addition, the AT value in the G-guide evaluation system required correction by the angle obtained in the preoperative epicondylar view. Intraoperative stem AT was defined as the sum of the intraoperative G-guide value and the correction angle. Postoperative AT was evaluated by CT examination. The discrepancy between the intra- and postoperative measurements was 4.6°±4.1°. Acceptable accuracy with discrepancy of less than 5° and 10° was achieved in 66 (69%) hips and 85 (89%) hips, respectively. The use of the G-guide could effectively reduce the variability of stem anteversion compared with manual adjustment. This study proved the effectiveness of the newly developed G-guide system in intraoperative stem AT adjustment. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 26881466     DOI: 10.3928/01477447-20160201-03

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  3 in total

1.  New combined anteversion technique in hybrid THA: cup-first procedure with CT-based navigation.

Authors:  Yoshinobu Masumoto; Shigeo Fukunishi; Tomokazu Fukui; Shinichi Yoshiya; Shoji Nishio; Yuki Fujihara; Shohei Okahisa; Taishi Okada; Makoto Kanto; Ariha Goshi; Futoshi Morio; Yu Takeda
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-11-08

2.  Measurement of operative femoral anteversion during cementless total hip arthroplasty and influencing factors for using neck-adjustable femoral stem.

Authors:  Jingyang Sun; Bohan Zhang; Lei Geng; Qingyuan Zheng; Juncheng Li; Wenzhe Cao; Ming Ni; Guoqiang Zhang
Journal:  J Orthop Surg Res       Date:  2021-05-31       Impact factor: 2.359

3.  A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty.

Authors:  Ryo Mitsutake; Hiromasa Tanino; Yasuhiro Nishida; Masaru Higa; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2020-02-19       Impact factor: 2.362