OBJECTIVE: The aims of our study were to verify the validity of the T-Scan III system (Tekscan) as an objective occlusal evaluation tool, and to assess the differences between two occlusal indexes-the peer assessment rating (PAR) index and the American Board of Orthodontics objective grading system (OGS)-by comparing the scores derived from the T-Scan III system with the two occlusal indexes and analyzing the correlations between them.Entities:
Keywords: Dental cast analysis; Occlusal evaluation; Orthodontic index; T-Scan
Year: 2016 PMID: 26877980 PMCID: PMC4751298 DOI: 10.4041/kjod.2016.46.1.27
Source DB: PubMed Journal: Korean J Orthod Impact factor: 1.372
Definitions of the T-Scan variables used in this study
Figure 1T-Scan overviews. A, Force distribution ratio of an maxillary left canine at D-point during left lateral excursion movement (canine guidance). B, The relative distribution of occlusal force is marked in each tooth as a green circle, and the arches are divided into four parts so that the relative distribution of the anterior-posterior occlusal forces on each side can be shown. C, The maximum area frame of the movie of maximum intercuspation was converted from contour lines to pixels, and the values were calculated. D, Representing the force outlier, the relative occlusal force for each tooth is the pink area.
Reliability test (Wilcoxon signed-rank test) and random error of T-Scan measurements
Refer to Table 1 for the definitions of all variables.
Descriptive statistics for the PAR index and OGS scores
Values are presented as mean±standard deviation.
PAR index, Peer assessment rating index; OGS, American Board of Orthodontics objective grading system.
Descriptive statistics for the T-Scan III system measurements
Values are presented as mean±standard deviation.
T-Scan III: Tekscan, Boston, MA, USA.
Refer to Table 1 for the definitions of all variables.
Spearman correlation analysis between the PAR index and the T-Scan III system
The values presented are correlation coefficients.
PAR index, Peer assessment rating index. T-Scan III: Tekscan, Boston, MA, USA.
Refer to Table 1 for the definitions of all variables.
*p < 0.05, †p < 0.01.
Spearman correlation analysis between the OGS and the T-Scan III system
The values presented are correlation coefficients.
OGS, American Board of Orthodontics objective grading system. T-Scan III: Tekscan, Boston, MA, USA.
Refer to Table 1 for the definitions of all variables.
*p < 0.05, †p < 0.01.
Figure 2Correlational analyses. A, Scattergram of the correlation between occlusal contact and Pro-DT. B, Scattergram of the correlation between OGS score and Occ-contact-Area. R, Correlation coefficient.